Calculation of ECO setpoint
temperature
When the mode is changed from Comfort to ECO, the value
displayed as setpoint temperature is:
•
Comfort setpoint – ECO setback (in heating)
or
•
Comfort se ECO setback (in cooling)
When the mode is changed from ECO to Comfort, the value shown
as setpoint temperature is only the setpoint.
5.9 Regulation selection
CD0000438
Description
Value
Default value
rt
Values
rt/rFt/rS
Mode
Icon
Sensor
Description
rt
Internal
Indoor temperature
The room temperature is
measured with the internal sensor
in the thermostat
rFt
Internal &
external
Indoor temperature with floor
temperature limitation
The room temperature is
measured with the internal sensor
in the thermostat, and the floor
temperature with external sensor
Press the key O (OK) to switch
between room temperature and
floor temperature
rS
External
Remote sensor temperature
The room or floor temperature is
measured with an external sensor
5.10 High limitation of floor
temperature
Note
This value is displayed only when the setting “
rEG
” is set
on "
rFt
".
CD0000443
Description
Value
Default value
26 °C
Step
0,5 °C
Values
20 °C (or "FL.L") to 35 °C
5.11 Low limitation of floor
temperature
Note
This value is displayed and set only if the parameter
“
rEG
” is set on "
rFt
".
CD0000446
Description
Value
Default value
20 °C
Step
0,5 °C
Values
10 °C to 30 °C (or "FL.H")
5.12 Calibration of internal room
sensor
Note
This menu is only displayed if the parameter "
rEG
" is set
with "
rt
" or "
rFt
".
Note
If the keys
―
and
+
are pressed simultaneously, the
sensor calibration is reset.
"
no
" is displayed
12
|
Uponor Base thermostat display T-27 230V
|
Installation and operation manual