background image

Installation 1

Installation 2

www.upshine.com   [email protected]

Step1

Step2

L

N

Step3

BLUE

BROWN

L =

N =

Step4

Step1

Step2

Put the LED batten back until it is stuck by clips.

Knock 2pcs plastic anchors into ceiling.

Fastening the clips on the ceiling.

Open the end cap, put the wires through the 

hole, connect the terminal block (Brown to L, 

Blue to N), tighten the end cap to prevent the 

water into the lamp.

Knock 2pcs plastic anchors into ceiling, fix the wire regulating 

device on ceiling.

Put the hook through metal plate, embed the metal plate in the slot 

of the lamp body.

100-130V

12

26

UP-DB18-1600-40W

200-277V

Linkable luminaries Qty

ART-NR

Содержание UP-DB18-1600-40W

Страница 1: ...Technical Application Guide for UP SHINE LED Batten Light UP DB18 1600 40W ...

Страница 2: ...luminate the ceiling 5 Colour rendering index CRI Ra 80 6 Impact protection IK10 7 LED service life approx 50 000 hours L80 B10 25 C 8 End caps made of shockproof polycarbonate PC 9 Extruded PC opal diffuser with inner prisms and UV resistant providing homogenous light distribution 10 Flexible installation through sliding mounting bracket Ideal for luminaire replacement 11 Providing through wiring...

Страница 3: ...Current output tolerance 5 Short circuit protection PASS Over voltage protection PASS Over temperature protection PASS THD 20 Withstand voltage Technical Specifications Model Voltage Power Power Factor Lumen 5 Beam angle CCT Lifespan CRI Dimmable Dimension UP DB18 1600 40W AC100 277V 40W 0 9 4080 140o 3000K 50000h 80 No 1600 78 53 5mm UP DB18 1600 40W AC100 277V 40W 0 9 4520 140o 4000K 50000h 80 N...

Страница 4: ...0 270 25 20 15 10 5 0 5 10 15 20 25 Height Eavg Emax Angle 110 70deg Diameter Note The Curves indicate the illuminated area and the average illumination when the Luminaire is at different distance Flux out 2043 lm Height Eavg Emax Angle 109 14deg Diameter Note The Curves indicate the illuminated area and the average illumination when the Luminaire is at different distance Flux out 2274 lm Height E...

Страница 5: ...19 10 16 37 10 Time Driver lifetime LED light decay rate 90000 80000 70000 60000 50000 40000 30000 20000 10000 0 65o C 75o C 85o C 95o C 105o C Lifetime hours Capacitor Tc o C Driver Lifetime LED Light Decay Rate Luminous Flux FLUX U V 110 105 100 95 90 85 80 75 70 0 0040 0 0035 0 0030 0 0025 0 0020 0 0015 0 0010 0 0005 0 0000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 LifeTime hours Tem...

Страница 6: ...ing the clips on the ceiling Open the end cap put the wires through the hole connect the terminal block Brown to L Blue to N tighten the end cap to prevent the water into the lamp Knock 2pcs plastic anchors into ceiling fix the wire regulating device on ceiling Put the hook through metal plate embed the metal plate in the slot of the lamp body 100 130V 12 26 UP DB18 1600 40W 200 277V Linkable lumi...

Страница 7: ...hone 86 755 2919 7389 Add 2nd building Dingfeng High Tech Zone Fuyuan 1st road Fu Yong Sub district Bao an Shenzhen China Step3 L N Step4 BLUE BROWN L N Adjust the length of suspending wires on same level turn on the light Hanging the lamp to the suspending wires Open the end cap put the wires through the hole connect the terminal block Brown to L Blue to N tighten the end cap to prevent the water...

Отзывы: