background image

 

 

 

 

-mounted Measuring Instrument

 

User Manual

 

 

Document Version: V1.00

 

 

Standing Pole

OTC-513

Содержание OTC-513

Страница 1: ...mounted Measuring Instrument User Manual Document Version V1 00 Standing Pole OTC 513...

Страница 2: ...rve safety specifications in this manual Screenshots provided in this document are used as examples only and the UI layout varies with versions This manual applies to multiple models but the models ar...

Страница 3: ...Device Management Indicates messages For example Hanging Up is displayed on the interface Directs you to go to a multi level menu For example go to Device Management Add Device In this example Add De...

Страница 4: ...5 2 3 4 Temperature Setting 6 2 3 5 Device Maintenance 6 3 Web Operations 7 3 1 Login 7 3 2 Network Configuration 9 3 2 1 Ethernet 9 3 2 2 DNS 11 3 2 3 Port Setting 11 3 2 4 DDNS 12 3 2 5 802 1x 12 3...

Страница 5: ...ii 4 FAQs 21...

Страница 6: ...in please follow the quick guide to complete the installation and power up 2 Local Operations 2 1 Main Interface 2 1 1 Not Measuring Temperature When the device is not measuring temperature environmen...

Страница 7: ...reensaver Mode It will enter the screensaver mode when there is no personnel temperature measurement or no operation for more than 30S default value If someone measures the temperature or touches the...

Страница 8: ...login The activation password is consistent with the password for the admin to log in to the Web interface If the activation password is changed use the new password to login On the Activation Config...

Страница 9: ...can modify the device IP address and other communication parameters so that the device can communicate with external devices 1 On the Activation Config interface tap to go to the Network Setting inter...

Страница 10: ...n Config interface tap to go to the Change Password interface 2 Enter the old password new password and confirm the new password as required NOTE The password must contain at least eight characters in...

Страница 11: ...5 42 Configure the range based on actual application scenes Temperature Alarm Threshold When the temperature measurement module detects a temperature higher than the threshold the abnormal temperature...

Страница 12: ...gin For operations to be performed when a dynamic IP address is assigned click Here for a reference The steps of logging in to the Web interface Internet Explorer 10 as an example are as follows 1 Ent...

Страница 13: ...me as the activation password If the activation password has been changed enter the new password here Enter the username and password based on the actual conditions Forgot Password If the user forgets...

Страница 14: ...If login fails six times consecutively the device locks automatically for ten minutes 3 2 Network Configuration 3 2 1 Ethernet Modify communication settings such as the IP address for the device so th...

Страница 15: ...set to DHCP complete the configuration by referring to the figure below The Dynamic Host Configuration Protocol DHCP is enabled by default when the device is delivered If a DHCP server is deployed in...

Страница 16: ...on 5 Click Save to complete the configuration 3 2 2 DNS 1 Click Setup Network DNS 2 Set Preferred and Alternate DNS server addresses 3 Click Save 3 2 3 Port Setting 1 Port 1 Click Setup Network Port G...

Страница 17: ...ss domain name username and password 5 Click Save 3 2 5 802 1x 802 1x provides authentication to devices trying to connect to a network Only the authenticated devices can connect the network This enha...

Страница 18: ...twork Security After security information transmission is set you can establish an information security channel to ensure data transmission security 1 HTTPS 1 Click Setup Security Network Security HTT...

Страница 19: ...1 255 255 255 255 224 0 0 1 5 Access Policy 1 Click Setup Security Network Security Access Policy 2 Select On to enable friendly password and MAC Authentication 3 Click Save NOTE Enabling friendly pa...

Страница 20: ...tion of temperature measurement module Choose Setup System Basic Info and click the External Device tab NOTE Only if Fireware Version and Hardware Version information are consistent the temperature me...

Страница 21: ...time zone System Time This parameter is available only when Sync Mode is set to Sync with System Configuration or Sync with Latest Server Time Configure the correct time Sync with Computer Time This p...

Страница 22: ...below Item Description Attribute Rule Configuration Temperature Measurement Temperature Measurement Measure Forehead Temperature The forehead temperature will be measured Measure Wrist Temperature The...

Страница 23: ...e device has an alarm output interface which can connect to alarm light alarm bell and so on When the high temperature alarm is triggered it will output a high or low level signal Perform the followin...

Страница 24: ...ange of 3s to 3600s The default value is 10s Standby Time s When the duration in which the device does not detect any personnel to measure temperature or operate reaches the time set here the devicel...

Страница 25: ...all parameters are restored to factory defaults except the administrator login password network port parameters system time admin password and activation password Restoring factory defaults completel...

Страница 26: ...essed file You need to decompress the file using a tool such as WinRAR and then open the file using a text editor By selecting Collect Image Debugging Info you can display image with debugging informa...

Страница 27: ...te https www uniview com b On the home page move the cursor over Support c Click Maintenance Tools d Locate the EZTools auxiliary tool software and download the software and user manual to the local d...

Отзывы: