OvEN
t
it
t
t
t
it
wF19 - laCK oF deterGeNt
Test
1
Measure the voltage applied to the detergent pump
Measure the
voltage applied to
the detergent
pump with the
multimeter set to
V AC
Is there any obstruction
(detergent filter clogged,
pipe pinched locked non-
return valve) from the tank to
the detergent pump?
Check if the pump is working
when the pressure switch
closes the circuit by
measuring the electrical
continuity with the
multimeter set to ohm
170