Univox PLS-100 Скачать руководство пользователя страница 1

How to connect a 1-turn / 2-turn loop

Balanced

Unbalanced

How to connect unbalanced / balanced input

Shield

Signal to pin 2 or 3

Disconnect the mains power before removing the cover!

IN1

Phantom power on (Default): S1 & S2 closed. Phantom power off: S1 & S2 open.
Microphone sensitivity (Default): S3 open. Line sensitivity: S3 closed.

IN2

Phantom power on: S5 & S6 closed. Phantom power off (Default): S5 & S6 open.
Microphone sensitivity: S4 open. Line sensitivity (Default): S4 closed.

Borrmall / Drill mask

Strap settings for Inputs 1 & 2

2-turn loop

1-turn loop

UniVox

®

UniVox

UniVox  PLS-100

®

®

Loop amplifi er 170m

2

Installation Guide

Page  4

2008-06-27    Z:\Products Public\Loop 

Amplifi

 ers - Systems\PLS-100\English\Service\PLS-100_IgGbV3.indd

Coverage area 170m² (free fi eld) 

according to IEC 60118-4:2006

2008-06-27

Telephone

+46 8 7671818

Telefax

+46 8 7671820

E-mail

[email protected]

Website

www.edin.se

Bo EDIN AB

Stockby Hantverksby 3

SE-181 75  LIDINGÖ

Sweden

WARNING!

Live terminals enclosed!

Отзывы: