Gas burning pizza brickoven
R-001 100518
Page 14 of 33
7.
ASSEMBLING INSTRUCTIONS
7.1
Clearances
WARNING
:
If this oven is not properly installed a fire may result.
To reduce the risk of fire, follow this installation instructions. A major cause of oven related
fire is failure to maintain required clearances (air spaces) to combustible materials. It is of
utmost importance that this oven be installed only in accordance with these instructions.
Please read this entire manual before you install the oven. Failure to follow instructions
may result in property damage bodily injury or even death. Contact your local building or
fire officials about restrictions and installation inspection in your area.
CLEARANCES
I)
The
Univex
oven must have a minimum 1" clearance to combustibles from all
size and 16" from combustibles from the top.
If building a facade that will contact the oven, use completely non-combustible
materials (when non-combustible building materials contact the body of the oven,
the clearances to combustibles are transferred to those non combustibles). Please
note that standard dry-wall (or sheet rock) is considered a combustible.
II)
Any facade above and/or 6 inches to either side of the oven doorway, must be
constructed of non combustible building materials
III)
Install this oven only on non combustible floors. The non combustible floor surface
should extend 40 inches out in front of the oven and extend 32 inches to either side
of the oven doorway.
IV)
Leave a clearance of at least 200cm
2
under the oven
V)
Leave a clearance for servicing and proper operation in case you are covering the
iron stand
WARNING: installation and servicing of this product could expose you to
glass wool/ceramic fibres and dust.
ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING OR
SERVICING THIS APPLIANCE