Universal Tool UT8716 Скачать руководство пользователя страница 1

Important

Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.

Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules

Operator Instructions

Manufacturer/Supplier

Product Type

RPM

Cycles Per Min

Model No/Nos

Serial No

Product Nett Weight

lbs
Kg

Recommended Use Of

Balancer Or Support

Recommended Hose Bore

Size - Minimum

Recommended Max.

Hose Length

Ins

M/M

Ft

M

No

Page No 1

2” Mini Angle Disc Grinder

UT8716
UT8716-BK

1.40
0.64

3/8

10

30

10

18,000

Universal Air Tool Company Limited
Unit 8
Lane End Industrial Park
High Wycombe
Bucks
HP14 3BY

Work Stations

The tool should only be used as a hand held hand operated tool. It is
always recommended that the tool is used when standing on a solid
floor. It can be used in other positions but before any such use the
operator must be in a secure position having a firm grip and footing and
be aware of the safety rules to be obeyed when using the sander.

Foreseen Use of Tool

This right angle grinder is designed to be used with reinforced resin
bonded depressed centre grinding wheels that have a permitted
rotational speed in excess of 18,000 RPM.
The tool is designed to be used for light grinding and dressing of welds,
etc. but not for cutting off. The grinder must never be used if a wheel
guard (disc cover) item (43) is not fitted.

Tel No

Fax No

(01494) 883300

(01494) 883237

Noise Level

Sound Pressure Level 83.0 dB(A)

Test Method

 Tested in accordance with Pneurop

test code PN8NTC1 and ISO Standard 3744

Vibration Level

Test Method

Tested in accordance with ISO

standards 8662/1 & 8662/4

Less than 2.5

Metres / Sec²

Putting Into Service

Air Supply

Use a clean lubricated air supply
that  will  give  a  measured  air
pressure  at  the  tool  of  90
p.s.i./6.3 bar when the tool is
running  with  the  trigger/lever
fully 

depressed. 

Use

recommended  hose  size  and
length. It is recommended that
the tool is connected to the air
supply as shown in figure 1. Do
not connect the tool to the air

line system without incorporating an easy to reach and operate air shut
off  valve.  The  air  supply  should  be  lubricated.  It  is  strongly
recommended that an air filter, regulator, lubricator (FRL) is used as
shown in Figure 1 as this will supply clean, lubricated air at the correct
pressure to the tool. Details of such equipment can be obtained from
your supplier. If such equipment is not used then the tool should be
lubricated by shutting off the air supply to the tool, depressurising the
line by pressing the trigger on the tool. Disconnect the air line and pour
into the intake bushing a teaspoonful (5ml) of a suitable pneumatic
motor lubricating oil preferably incorporating a rust inhibitor. Reconnect
tool to air supply and run tool slowly for a few seconds to allow air to
circulate the oil. If tool is used frequently lubricate on daily basis and if
tool starts to slow or lose power.
It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar. The tool can run at lower and higher
pressures with the maximum permitted working air pressure of 100
p.s.i./7 bar.

Personal  Safety  Equipment

Use  -  Safety  Glasses

Yes

Use  -  Safety  Gloves

Yes

Use  -  Safety  Boots
Use  -  Breathing  Masks

Yes

Use  -  Ear  Protectors

Yes

Air  Pressure

Recommended  Working

6.3

bar

90

PSI

Recommended  Minimum

n/a

bar

n/a

PSI

Maximum

7.0

bar

100

PSI

Отзывы: