background image

Manufacturer/Supplier

Product Type

RPM

Cycles Per Min

Model No/Nos

Serial No

Product Nett Weight

lbs
Kg

Recommended Use Of

Balancer Or Support

Recommended Hose Bore

Size - Minimum

Recommended Max.

Hose Length

Ins

M/M

Ft

M

Foreseen Use of Tool

This tool is designed for the purpose of driving staples for only the
sizes as indicated in the section “Operating”. Do not use the tool for
any other purpose. Do not modify the tool to be used for any other
purpose or for its use as a stapler without first agreeing any such
modifications with the manufacturer or an authorised distributor.

Putting Into Service

Air Supply

Use a clean lubricated air supply
that will give a measured air
pressure at the tool of 90
p.s.i./6.3 bar when the tool is
running with the trigger fully
depressed. Use recommended
hose size and length. It is
recommended that the tool is
connected to the air supply as
shown in figure 1. Do not
connect the tool to the air line

Work Stations

The tool should only be used as a handheld, hand operated tool.  It is
always recommended that the tool is used when standing on a solid
floor.  It can be used in other positions but before any such use, the
operator must be in a secure position having a firm grip and footing
and be aware of a reaction force on the hand as result of the tool
doing work.

No

Air Pressure

Recommended Working

6.3

bar

90

PSI

Recommended Minimum

n/a

bar

n/a

PSI

Maximum

7.0

bar

100

PSI

Personal Safety Equipment

Use - Safety Glasses

Yes

Use - Safety Gloves
Use - Safety Boots
Use - Breathing Masks
Use - Ear Protectors

Yes

Page No 1

10mm Stapler

UT021A (HP021)

2.42

1.1

3/8

10

30

10

Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules

Operator Instructions

Important

Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.

Noise Level

Sound Pressure Level 88.4 dB(A)

Test Method

 Tested in accordance with ISO

Standard 3744

Peak C Level 116.0 dB(A)

Vibration Level

Test Method 

Tested in accordance with ISO

standard 8662/1

4.4

Universal Air Tool Company Limited
Unit 8
Lane End Industrial Park
High Wycombe
Bucks
HP14 3BY

Tel No

Fax No

(01494) 883300

(01494) 883237

Metres / Sec²

system without incorporating an easy to reach and operate air shut off
valve. The air supply should be lubricated. It is strongly recommended
that an air filter, regulator, lubricator (FRL) is used as shown in Figure
1 as this will supply clean, lubricated air at the correct pressure to the
tool. Details of such equipment can be obtained from your supplier. If
such equipment is not used then the tool should be lubricated by
shutting off the air supply to the tool, depressurising the line by
pressing the trigger on the tool. Disconnect the air line and pour into
the intake bushing a teaspoonful (5ml) of a suitable pneumatic motor
lubricating oil preferably incorporating a rust inhibitor. Reconnect tool
to air supply and run tool slowly for a few seconds to allow air to
circulate the oil. If tool is used frequently lubricate on daily basis and if
tool starts to slow or lose power.
It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar. The tool can run at lower and higher
pressures with the maximum permitted working air pressure of 100
p.s.i./7.0 bar.

N/A

N/A

Содержание UT021A

Страница 1: ...s Page No 1 10mm Stapler UT021A HP021 2 42 1 1 3 8 10 30 10 Includes ForeseenUse WorkStations PuttingIntoService Operating Dismantling Assembly and Safety Rules Operator Instructions Important Read these instructions carefully before installing operating servicing or repairing this tool Keep these instructions in a safe accessible place Noise Level Sound Pressure Level 88 4 dB A Test Method Tested...

Страница 2: ...sconnect tool from air supply Gripbody 19 inavicefittedwithsoftjawsandremoveairplug 32 Take out 2 off screws 38 and operate click lever 37 and slide off stapleguideunit 43 Slideoffpusher 42 anddisengagefromeach end of pusher spring 41 Unscrew nut 36 from hex bolt 1 and removebothitems Unscrew2offscrews 1 andremovespacer 34 andpulloffmagazineunit 35 withdriverguide 44 Remove E ring 30 andpulloutste...

Страница 3: ...e 18 AH 04125 Special O Ring 19 AL 11022 Body 20 AL 11011 Nozzle 21 AL 11012 Trigger 22 AF 30150 Stepped Pin Ref No Part No Description 23 AH 12515 Seal 24 AL 11013 Trigger Valve Head 25 AL 11014 Trigger Valve Stem 26 AH 03515 Special O Ring 27 AL 11015 Trigger Valve Guide 28 AH 11020 O Ring 29 AK 80145 Compression Spring 30 AJ 40023 E Ring 2 31 AL 11031 Piston Cover Driver 32 AL 11008 Air Plug 33...

Страница 4: ...another person 18 When completing work task or leaving the tool for a period of time takeoutallthefastenersfromthemagazineandbesurenotto leave any fastener in the firing head 19 Periodically check all screws for tightness Tighten any loose screws before proceeding to use tool Declaration of Conformity Universal Air Tool Company Limited Unit 8 Lane End Industrial Park High Wycombe Bucks HP14 3BY En...

Отзывы: