Manufacturer/Supplier
Product Type
RPM
Cycles Per Min
Model No/Nos
Serial No
Product Nett Weight
lbs
Kg
Recommended Use Of
Balancer Or Support
Recommended Hose Bore
Size - Minimum
Recommended Max.
Hose Length
Ins
M/M
Ft
M
Foreseen Use of Tool
This tool is designed for the purpose of driving staples for only the
sizes as indicated in the section “Operating”. Do not use the tool for
any other purpose. Do not modify the tool to be used for any other
purpose or for its use as a stapler without first agreeing any such
modifications with the manufacturer or an authorised distributor.
Putting Into Service
Air Supply
Use a clean lubricated air supply
that will give a measured air
pressure at the tool of 90
p.s.i./6.3 bar when the tool is
running with the trigger fully
depressed. Use recommended
hose size and length. It is
recommended that the tool is
connected to the air supply as
shown in figure 1. Do not
connect the tool to the air line
Work Stations
The tool should only be used as a handheld, hand operated tool. It is
always recommended that the tool is used when standing on a solid
floor. It can be used in other positions but before any such use, the
operator must be in a secure position having a firm grip and footing
and be aware of a reaction force on the hand as result of the tool
doing work.
No
Air Pressure
Recommended Working
6.3
bar
90
PSI
Recommended Minimum
n/a
bar
n/a
PSI
Maximum
7.0
bar
100
PSI
Personal Safety Equipment
Use - Safety Glasses
Yes
Use - Safety Gloves
Use - Safety Boots
Use - Breathing Masks
Use - Ear Protectors
Yes
Page No 1
10mm Stapler
UT021A (HP021)
2.42
1.1
3/8
10
30
10
Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules
Operator Instructions
Important
Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.
Noise Level
Sound Pressure Level 88.4 dB(A)
Test Method
Tested in accordance with ISO
Standard 3744
Peak C Level 116.0 dB(A)
Vibration Level
Test Method
Tested in accordance with ISO
standard 8662/1
4.4
Universal Air Tool Company Limited
Unit 8
Lane End Industrial Park
High Wycombe
Bucks
HP14 3BY
Tel No
Fax No
(01494) 883300
(01494) 883237
Metres / Sec²
system without incorporating an easy to reach and operate air shut off
valve. The air supply should be lubricated. It is strongly recommended
that an air filter, regulator, lubricator (FRL) is used as shown in Figure
1 as this will supply clean, lubricated air at the correct pressure to the
tool. Details of such equipment can be obtained from your supplier. If
such equipment is not used then the tool should be lubricated by
shutting off the air supply to the tool, depressurising the line by
pressing the trigger on the tool. Disconnect the air line and pour into
the intake bushing a teaspoonful (5ml) of a suitable pneumatic motor
lubricating oil preferably incorporating a rust inhibitor. Reconnect tool
to air supply and run tool slowly for a few seconds to allow air to
circulate the oil. If tool is used frequently lubricate on daily basis and if
tool starts to slow or lose power.
It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar. The tool can run at lower and higher
pressures with the maximum permitted working air pressure of 100
p.s.i./7.0 bar.
N/A
N/A