Specifications
System Operating Environment Requirements (user provided)
Models
PLS3.60 PLS4.60
PLS6.60
PLS6.120D
Operating
Environment
Well-ventilated office (recommended) or clean, light-duty manufacturing
Operating
Temperature
50ºF (10ºC) to 95ºF (35º C) capable
73ºF (22ºC) to 77ºF (25º C) for best performance
Storage Temperature
50ºF (10ºC) to 95ºF (35º C)
Operating Humidity
Non-condensing
Electrical Power
Single Phase 110/230V AC, 10/5 Amp, 50/60 Hz
Grounded (earthed) and stable (surge and spike protected)
High-pressure vacuum blower capable of:
Particulate/Odor
Outside Ventilated
Exhaust System
250 CFM (cubic feet per minute) @ 6
inches static pressure
(425m3/hr at 1.5kPa)
500 CFM (cubic feet per minute)
@ 6 inches static pressure