Page | 224
know that they must be skipped over until you get back to the correct ID number
location. If you have already used some of the variable locations for other programs,
you must either redirect your current program to another ID location or redirect the
appropriate variables from these programs to new ID locations. You are free to
change the names if you like so long as you understand what it represents.
•
Import the programs or undertake the task of manually entering the programs.
Please observe the screen captures to see how I set up the folder architecture. You
are certainly free to do it differently, but keeping the programs organized this way is
helpful. Here is a link to a zipped version of the file. Please unzip the file first and
then import it.
devices.com/programs/calendar/mmddyyyy.zip
•
Set the start values. You must set the current date including day of month, day of
year, month, day of week, year, and leap year and leap year (0 for leap year, 1 for the
year after a leap year, etc.) variables to the correct values. If you would like to stay
true to the day counter starting with 1 on Jan 1, 1900 then you need to cross
reference that number to MS Excel. This is an arbitrary decision on your part as any
number would actually work. All of the other variables are calculated from those
values and will settle in when the programs run at midnight. The “init” values need
not be set as they will automatically populate at the midnight run time (unless you
reboot your ISY prior to that time in which case all of the values will be lost).
•
Go to the Configuration Tab, System sub tab, System box and Uncheck the box next
to “Catch up Schedules at Restart”. Not
doing so will cause your ISY to run these
programs every time the ISY is rebooted pushing it one day into the future which in
most cases will be an error. Missed schedule grace period should be left at 15
minutes.
•
Setup the email at ID location number 1 to whom you want the email sent and what
you would like the content to be in the event that the ISY’s day of week becomes out
of sync with the day of week calculated by these programs. It is assumed that if this
variable is accurate, all of the others will be as well. Furthermore, it is the only thing
that is possible for ISY to test on its own.
11.1.1.4Potential Pitfalls
The primary reason for a fault is a power failure or otherwise taking the ISY offline. If the
ISY is continuously not operating between 12 midnight and 12:15 am the programs will fall
one day behind. To manually push the programs one day forward, right click on “Advance
Day” program and click “run then”. You can do this repeatedly to advance several days
forward. The ISY was tested by me to function properly through the year 2015. I did not
actually run the program any further out than that but I have no reason to believe it should
fail. It is designed to run correctly for several hundred years before the leap year issue no
longer is accurate. I trust that will not cause you any inconvenience. At the time of this
writing, these programs have been up and running real time for about 4 months without
error. Based on this and my tests running these programs through to 2015 in “fake time” I
suspect there are no errors.
Содержание ISY-994i Series
Страница 1: ...The ISY 994i Home Automation Cookbook ...
Страница 35: ...Page 12 Figure 6 UDAjax Main Screen ...
Страница 36: ...Page 13 Figure 7 UDAjax Devices Scenes Screen ...
Страница 68: ...Page 45 Figure 44 NodeServer Configuration popup 5 2 5 Tools Menu Figure 45 Tools Menu ...
Страница 98: ...Page 75 You should now see local weather information as shown below Figure 73 Local Weather Information ...
Страница 102: ...Page 79 6 6 3 2Activate My OpenADR Portlet Figure 77 OpenADR My OpenADR Menu Option ...
Страница 103: ...Page 80 6 6 3 3Configure OpenADR Settings Figure 78 OpenADR Settings Menu Option ...
Страница 104: ...Page 81 Figure 79 OpenADR Settings Display ...
Страница 108: ...Page 85 6 6 3 7Issue an Event Figure 84 OpenADR Issue and Event ...
Страница 109: ...Page 86 Figure 85 OpenADR Events You can use the Event Viewer to see the operational status of ISY and OpenADR events ...
Страница 110: ...Page 87 Figure 86 OpenADR Event Viewer ...
Страница 116: ...Page 93 Figure 92 ElkRP2 Account Details M1XEP Setup Button In the M1XEP Setup Window ...
Страница 267: ...Page 244 Figure 189 State Variables ...
Страница 268: ...Page 245 Figure 190 Programs and Folders ...
Страница 292: ...Page 269 Figure 192 Irrigation Folders Figure 193 Irrigation Devices ...
Страница 376: ...Page 353 Figure 209 Save Topology File ...
Страница 433: ...Page 410 Figure 242 X 10 recognized as Living Room East Device ...
Страница 461: ...Page 438 Figure 259 HAM Weather Data 17 2 2 Irrigation Module s Settings Figure 260 Irrigation Cycle Calculator ...
Страница 531: ...Page 508 Figure 342 Base Task Dependencies 1 Click the bottom center of screen In the Filter type http Touch HTTP Get ...
Страница 536: ...Page 513 Figure 349 In Car Detection 5 Figure 350 In Car Detection 6 In the filter type BT and then select BT Connected ...
Страница 540: ...Page 517 Figure 357 In Car Detection 12 Figure 358 In Car Detection 13 ...
Страница 602: ...Page 579 Figure 382 SecureCRT SSH Raspberry PI Session ...
Страница 620: ...Page 597 Figure 397 HyperTerminal Login The ISY Shell is displayed All input to the ISY shell must be in UPPER CASE ...
Страница 660: ...Page 637 Figure 420 ISY Select file Your ISY will now update the firmware and reboot when it is finished ...
Страница 675: ...Page 652 create surges at power on such as traditional fluorescent lights and general purpose electrical sockets ...
Страница 685: ......