Unitronics Industrial Automation Systems 

 

EX-A1       

I/O Expansion Module Adapter

 

The EX-A1 interfaces between a variety of 
I/O expansion modules and specific 
Unitronics’ OPLCs. 

A single adapter can be connected to up to 
8 expansion modules.  

The EX-A1 may either be snap-mounted 
on a DIN rail, or screw-mounted onto a 
mounting plate. 

 

Component identification 

1 Status 

indicators 

OPLC to EX-A1 connection port 

Power supply connection points 

EX-A1 to expansion module  
connection port 

 

2

1

2

3

4

 

User safety and equipment protection guidelines 

This document is intended to aid trained and competent personnel in the installation of this equipment as defined 
by the European directives for machinery, low voltage and EMC. Only a technician or engineer trained in the local 
and national electrical standards should perform tasks associated with the electrical wiring of this device. 

 

Under no circumstances will Unitronics be liable or responsible for any consequential damage that may 
arise as a result of installation or use of this equipment, and is not responsible for problems resulting from 
improper or irresponsible use of this device. 

 

All examples and diagrams shown in the manual are intended to aid understanding.  They do not 
guarantee operation. 

 

Unitronics accepts no responsibility for actual use of this product based on these examples. 

 

Only qualified service personnel should open this device or carry out repairs. 

 

Please dispose of this product in accordance with local and national standards and regulations. 

 

 

Check the user program before running it. 

 

Do not attempt to use this device with voltage exceeding permissible levels. 

 

Install an external circuit breaker and take all appropriate safety measures against short-
circuiting in external wiring. 

 

 

 

 

Failure to comply with appropriate safety guidelines can result in severe personal injury or 
property damage.  Always exercise proper caution when working with electrical equipment. 

 

Содержание EX-A1

Страница 1: ...his device Under no circumstances will Unitronics be liable or responsible for any consequential damage that may arise as a result of installation or use of this equipment and is not responsible for problems resulting from improper or irresponsible use of this device All examples and diagrams shown in the manual are intended to aid understanding They do not guarantee operation Unitronics accepts n...

Страница 2: ...ving a minimum space of 10mm between the top and bottom edges of the device and the enclosure walls Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation DIN rail mounting Snap the EX A1 onto the DIN rail as shown below the EX A1 will be squarely situated on the DIN rail 60mm 3 5mm 14mm 80mm 93mm 44 5mm Screw Mounting The figure on th...

Страница 3: ...12 01 EX A1 I O Expansion Module Adapter Unitronics Industrial Automation Systems 3 4mm 5 8mm 85mm 80mm 68 4mm 93mm 4mm x2 ...

Страница 4: ...nnectors The cable provided with the EX A1 is one meter long cables of other lengths are available by separate order Note that the cable must be earthed on the M90 side via the yellow green wire To avoid damaging the system do not connect or disconnect the device when the power is on I O expansion port Earth M90 EX A1 Shielded RJ45 connector pin out Cable description Pin 1 RJ 45 pin 8 1 2 4 3 6 D ...

Страница 5: ...tive to the 0V terminal A non isolated power supply can be used provided that a 0V signal is connected to the chassis Note that both the OPLC and the EX A1 must be connected to the same power supply Circuit protection device 0V V 12VDC or 24VDC power supply Do not use tin solder or any other substance on the stripped wire that might cause the wire strand to break We recommend that you use crimp te...

Страница 6: ...supplied COMM Green indicator lit when communication is established Environmental IP20 NEMA1 Operating temperature 0 to 50 C 32 to 122 F Storage temperature 20 to 60 C 4 to 140 F Relative Humidity RH 5 to 95 non condensing Dimensions WxHxD 80mm x 93mm x 60mm 3 15 x 3 66 x 2 362 Weight 125g 4 3oz Mounting Either onto a 35mm DIN rail or screw mounted Notes 1 Both the OPLC and the EX A1 must be conne...

Страница 7: ...n module identification number Adapter The formula below is used to assign addresses for I O modules used in conjuction with the M90 OPLC X is the number representing a specific module s location 0 7 Y is the number of the input or output on that specific module 0 15 The number that represents the I O s location is equal to 32 x 16 y Examples Input 3 located on expansion module 2 in the system wil...

Страница 8: ...EX A1 I O Expansion Module Adapter 12 01 8 Unitronics Industrial Automation Systems ...

Отзывы: