background image

 

 

 

PROBLEM

 

CASE

 

SOLUTION

 

The machine does not 
switch on.

 

Lack of power supply   
 

 
 

Voltage reaches the machine switch 

but there is no voltage after the 

contacts.   

 
 

 
 

There is voltage after the 

disconnecting switch but the 

machine does not go on.   

 

 
There is voltage after the 

disconnecting switch but the 
machine does not go on. The 

LED L1 is on.

 

Make sure the line switch is closed, the 

protection devices (fuses) are not enabled 

and that the power supply cable is in good 
condition (Picture 3). 

Switch the machine off and disconnect the plug. 

Make sure that when the switch is closed, 

there is continuity between the contact input 

and output (Picture 3) and the varistor is not 
broken. If broken, replace board 0074. 

(Picture 1). 

 

Switch the machine off and disconnect the plug. 

Check the PFC Module on the power board, 

if it is damaged, replace the power board 
(Picture 2)   

 
You have to check if the LED on rear panel is 

on. (Picture 4).You have to check the value 
of the main power supply.   

The protection devices 
of the line set off when 

the switch is activated 
and the machine does 
not go on.

 

Damaged  power  supply  cable  with 

short-circuited  wires.  Inverter  is 

damaged.

 

Switch off the machine and disconnect the plug. 

Make  sure  that  there  are  no  short  circuits 

between  the  poles  of  the  plug  caused  by  a 
damaged power supply cable.   

Switch off the machine and disconnect the plug, 

then check : 

-  varistor (Picture 1); 
if it is damaged, replace the board 0074; 

-      check  the  PFC  Module  and  Inverter   
(Picture 2,6) 

if they are damaged, replace the power board 
0070; 

Input bridge rectifier (Picture 5); 
if it is damaged, verify also inverter and PFC 

module. 
If they are working then replace only the Input 

rectifier, otherwise both.

 

 
 
 
 

CAUTION! 

Before carrying out any work on the machine 
make  sure  it  is  off  and  the  plug  has  been 
disconnected. 

Содержание UWI-230TP

Страница 1: ...Ultima modifica Last Update 08 10 2015 Rev1 0 UWI 230TP ACDC Reparation Manual UWI 230TP AC DC...

Страница 2: ......

Страница 3: ...rd if it is damaged replace the power board Picture 2 You have to check if the LED on rear panel is on Picture 4 You have to check the value of the main power supply The protection devices of the line...

Страница 4: ...Picture 8 Replace it and if it is still not working replace the Power Board Replace Power Board 0070 The output voltage in MMA TIG is about 13 5V and the Machine doesn t weld The wires that connect th...

Страница 5: ...ent The remote control is damaged Check that the 4 pin connector picture 13 is correctly inserted on the front panel The Front Panel could be damaged Insert the wires into the connectors correctly and...

Страница 6: ...f while welding AC Make sure welding polarity is correct the earth clamp is fixed correctly and check the hot start and arc force values that have to be decreased if they are too high The inversion bo...

Страница 7: ...of the short circuit is very high they become an open circuit Picture 2 To check the PFC of the switching power supply unit carry the following measurements with a diode tester Should there be a short...

Страница 8: ...ou have to check the continuity with a diode tester between points D1 F1 and D2 F2 If there is no continuity you have to check the single parts Picture 4 If you see L1 ON the OVERCAT is working Check...

Страница 9: ...rectifier must be replaced Rheofore Probe Rheofore Probe F Rosso D1 D2 Nero F Rosso D1 D2 Nero F Nero D1 D2 Rosso F Nero D1 D2 Rosso Picture 6 To check the inverter carry out the following measuremen...

Страница 10: ...wo terminals of the thermal devices are well inserted in the 8 pin white connector on the power board 0070 Picture 8 Make sure that the fan cables 24 V are correctly inserted 2 pin connector on the po...

Страница 11: ...he Vout cable Red Probe Black Probe Measure Pin 4 of the amphenol Negative Socket OL Pin 8 of the amphenol Positive shocket OL Make sure that the output filter board 0074 cables are correctly inserted...

Страница 12: ...SX red UP DOWN black 0 3 SX black UP DOWN red OL DX red UP DOWN black OL DX black UP DOWN red 0 3 At the ends of the two transils see below positioned on the snubber board OL must always be measured C...

Страница 13: ...s MEMORY RESETTING Picture 12 Check continuity with a diode tester between points A Y of the power board and B X poles of the connector that goes to the front panel Connect the MINIFIT 4 PINS at the p...

Страница 14: ...ture 13 Checking the remote cable With a tester diode mode check the data table follow Probe red Probe black Misura C 9 OL D 4 OL E 3 OL Picture 14 Check if the flat cable has a good connection in the...

Страница 15: ......

Отзывы: