Revision date 11.02.2014
Page 5 of 20
I
2
= Welding current.
Range 5
– 150A
U
r
= Reduced open circuit voltage
Is the voltage (excluded any stabilization voltage or arc ignition) found between the output outlets
when the welding machine is not welding. This is the voltage a welder can be exposed to between
electrode holder and work piece.
U
2
= Arc voltage
Voltage present between the output outlets when welding is being carried out, in relation to a
particular set current. The relation, for the various welding modes is the following:
MMA→ U2=(20+0,04*I2)
TIG → U2=(10+0,04*I2)
Primary connection
U
1
= Effective input voltage 230V
I
1max
= Maximum value of input current at the corresponding duty cycle.
I
1eff
= Effective value of input current at the corresponding duty cycle.
Cooling
COOLING AF= Forced air cooling (with a fan).
Protection class
IP23S= Ingress Protection class. Protection degree of the casing according to EN 60529
2: Protection against object not greater than 80mm in length and 12mm in diameter
3: Protection from sprayed water at an angle of 60º from vertical
S: Valid at standstill. (Should not be used for welding outdoors in heavy wind and rain)
Thermal insulation class
I.CL.H= Thermal class of the insulating materials and insulation systems.
resistant up to 180°C.
Standards
EN 60974-10 European Norm for electromagnetic compatibility.
EN 60974-1 European Norm for arc welding appliance: Current sources for welding.
Mark stating conformity to all safety standards and other standards required for sale
within the European Union
Dimensions and weight
Height : 215mm
Length : 310mm
Width : 120mm
Weight : 4,4kg
H
H
L
W