Main arc:
When the pilot arc gets in contact with the cutting material D15 and D25 lights up indicating
that the signal for contact with material has been detected and the Control & ignition pcb is
activating the cutting flow, switching off pilot transistor and increasing current from pilot
current to cutting current.
Post flow:
After finished cutting cycle D17 and D25 remains on for approx. 30secs in order for the torch
to cool down after finished cutting cycle.
If any discrepancies change the E3 Ignition & Control PCB.