Revision date: 120813
Page 28 of 46
Check the E4 Secondary PCB.
These measurement are all made at room temperature 20°C, if the machine is used recently the
values may differ.
Disconnect one of the main transformer leads and one of the choke leads.
Measure between D3A and D3B with diode test and the red probe on D3B.
Correct value is approx. 0.35. If a low value or a short is measured replace the diode module
D3/D4.
Measure between D2A and D2B with diode test and the red probe on D2B.
Correct value is approx. 0.35. If a low value or a short is measured replace the diode module
D1/D2.