Check the voltages on the T1 Control transformer, between 0 and 230 on the primary side.
If low or not existing check the fuse on the control transformer. If fuse is undamaged replace
the control transformer.
If fuse is broken replace the fuse and try again. If the fuse breaks again then disconnect the fan
by removing connector A7 on the E2 Control PCB. Replace the fuse and recheck the voltage,
if correct replace the fan.