Revision date: 120813
Page 21 of 46
Check supply and system voltage.
Connect the machine to mains supply.
Check the incoming voltage between all three phases. Correct value is 400 or 440VAC
depending on the supply voltage. If one phase is missing check the mains fuses.
Switch on the machine.
Check the voltage on the D5 main rectifier between
cable
no.
73
and
74
positive probe
on
cable
73
. Correct value is approx 620VDC if connected to 440VAC and 560VDC if connected
to 400VAC. If voltage is low recheck the main supply fuses, EMC-Filter, B1 switch and D5
main rectifier.