Revision date: 120813
Page 20 of 46
Measure between
cable
no.
73
and the
Out (+)
on the
E1 primary pcb
with the meter set to
diode test
and
negative probe
on
cable 73
. Correct value is approx. 0.35. This value may
differ a bit between different instruments but if very low or a short is measured then replace
the E1 primary PCB.
Reconnect cable 73 and 74 to the D5 main rectifier.
Содержание UPC 1041
Страница 1: ...Revision date 120813 Page 1 of 46 Instruction manual UPC 1041 Air Plasma Cutter...
Страница 38: ...Revision date 120813 Page 38 of 46...
Страница 39: ...Revision date 120813 Page 39 of 46...
Страница 40: ...Revision date 120813 Page 40 of 46...
Страница 41: ...Revision date 120813 Page 41 of 46...
Страница 42: ...Revision date 120813 Page 42 of 46...
Страница 43: ...Revision date 120813 Page 43 of 46 Notes...
Страница 44: ...Revision date 120813 Page 44 of 46 Notes...
Страница 45: ...Revision date 120813 Page 45 of 46...