Check the D5 main rectifier.
Verify that the machine is disconnected from the mains supply.
Measure with instrument set to diode test, place the
positive probe
on cable
74
and the
negative probe
on cable
11 , 21 and 31
. Correct value is approx 0.5V this can differ slightly
between instruments. If a short is measured then replace the D5 main rectifier.
Measure with instrument set to diode test, place the
negative
probe on cable
73
and the
positive
probe on cable
11 , 21 and 31
. Correct value is approx 0.5V this can differ slightly
between instruments. If a short is measured then replace the D5 main rectifier.