Check the B1 Main switch.
Verify that the machine is disconnected from the mains supply.
Turn on the Main switch. Remove the fuse from the T1 Control transformer.
Measure between the cables 11, 21 and 31 and the three phases on the incoming side on the
main switch with a resistance or summer measurement.
Correct value is 0 Ohm, if resistance is high then replace the B1 main switch
Replace the fuse on the T1 control transformer and switch off B1 main switch.