Multiprocess Welding

OM-202 137V

2012−01

Description

Arc Welding Power Source

UWI 400

(380/440 Volt Model) CE

Содержание UNITOR UWI 400

Страница 1: ...Processes Multiprocess Welding OM 202 137V 2012 01 Description Arc Welding Power Source UWI 400 380 440 Volt Model CE...

Страница 2: ......

Страница 3: ...Symbols And Definitions 14 SECTION 4 INSTALLATION 15 4 1 Important Information Regarding CE Products Sold Within The EU 15 4 2 Serial Number And Rating Label Location 15 4 3 Specifications 15 4 4 Duty...

Страница 4: ...108 EC Electromagnetic Compatibility Standards IEC 60974 1 2005 Arc Welding Equipment Welding Power Sources IEC 60974 10 2007 Arc Welding Equipment Electromagnetic Compatibility Requirements EN 50445...

Страница 5: ...ds when in cramped positions such as sitting kneeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following eq...

Страница 6: ...ums or pipes unless they are properly prepared according to AWS F4 1 and AWS A6 0 see Safety Standards D Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as gasoli...

Страница 7: ...NG PARTS can injure D Keep away from moving parts such as fans D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards...

Страница 8: ...ntion During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org OSHA Occupational Safety and Healt...

Страница 9: ...utilisation d une source lectrique courant lectrique s av re n cessaire se servir de la fonction de t l commande si l appareil en est quip D D autres consignes de s curit sont n cessaires dans les con...

Страница 10: ...ine et des bottes de protection LE SOUDAGE peut provoquer un incendie ou une explosion Le soudage effectu sur des conteneurs ferm s tels que des r servoirs tambours ou des conduites peut provoquer leu...

Страница 11: ...eur D Utiliser les quipements corrects les bonnes proc dures et suffi samment de personnes pour soulever et d placer les bouteilles D Lire et suivre les instructions sur les bouteilles de gaz comprim...

Страница 12: ...der seulement des personnes qualifi es familiaris es avec des quipements lectroniques de faire fonctionner l installa tion D L utilisateur est tenu de faire corriger rapidement par un lectricien quali...

Страница 13: ...t Q and Part 1926 Subpart J from U S Government Printing Office Super intendentof Documents P O Box 371954 Pittsburgh PA 15250 7954 phone 1 866 512 1800 there are 10 OSHA Regional Offices phone for Re...

Страница 14: ...OM 202 137 Page 10...

Страница 15: ...welding fumes can be hazardous to your health 2 1 Keep your head out of the fumes 2 2 Use forced ventilation or local exhaust to remove the fumes 2 3 Use ventilating fan to remove fumes 3 Welding spa...

Страница 16: ...There are possible hazards as shown by the symbols 2 When power is applied failed parts can explode or cause other parts to explode 3 Flying pieces of parts can cause injury Always wear a face shield...

Страница 17: ...conductors and total length as specified in the table 4 Table showing correct conductor sizes and total length of cord 1 96 2 3 4 1 202563 B 3 2 WEEE Label Do not discard this product with general was...

Страница 18: ...rol Line Connection Arc Force Shielded Metal Arc Welding SMAW Gas Metal Arc Welding GMAW Three Phase Static Frequency Con verter Transformer Rectifier U0 Rated No Load Voltage Average U1 Primary Volta...

Страница 19: ...tion On Electromagnetic Compatibility EMC This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There c...

Страница 20: ...an runs Wait fifteen minutes for unit to cool Reduce amperage or duty cycle be fore welding NOTICE Exceeding duty cycle can damage unit and void warranty 60 Duty Cycle Overheating 0 15 A OR Reduce Dut...

Страница 21: ...2B thread Weight 76 lb 34 6 kg 4 7 Selecting a Location Ref ST 151 556 801 192 1 Lifting Handles Use handles to lift unit 2 Hand Cart Use cart or similar device to move unit 3 Line Disconnect Device L...

Страница 22: ...30 2 35 1 50 1 0 60 1 0 60 150 3 30 3 30 2 35 1 50 1 0 60 2 0 70 3 0 95 3 0 95 200 3 30 2 35 1 50 1 0 60 2 0 70 3 0 95 4 0 120 4 0 120 250 2 35 1 50 1 0 60 2 0 70 3 0 95 4 0 120 2x2 0 2x70 2x2 0 2x70...

Страница 23: ...tector CB1 J Contact closure to I completes 115 volts AC con tactor control circuit REMOTE OUTPUT CONTROL C Output to remote control 0 to 10 volts DC 10 volts DC in MIG mode D Remote control circuit c...

Страница 24: ...ss than the rating of the circuit protection device All components of the circuit must be physically compatible See NEC articles 210 21 630 11 and 630 12 50 60 Hz Three Phase Input Voltage V 380 440 I...

Страница 25: ...1 Input Power Cord 2 Disconnect Device switch shown in the OFF position 3 Green Or Green Yellow Grounding Conductor 4 Disconnect Device Grounding Terminal 5 Input Conductors L1 L2 And L3 6 Disconnect...

Страница 26: ...most modes remote control is a percent of the Voltage Amperage Adjustment control setting the value se lected on Voltage Amperage Adjustment control is maximum available on remote In the MIG mode remo...

Страница 27: ...arc is broken Mode Meter Reading At Idle Lift Arc Trigger Hold TIG GTAW V A Blank Preset Amps 85 TIG GTAW Blank Preset Amps V A 85 MIG GMAW Preset Volts Blank V A 24 5 Pulsed MIG GMAW P Pulse Display...

Страница 28: ...ctrode sticking at arc start Mode Output Control Lift Arc Trigger Hold TIG GTAW Select or Amp Requires Control TIG GTAW With HF Unit Pulsing Device Or Remote Control Select or Amp Requires Control MIG...

Страница 29: ...put switch Slowly lift electrode An arc will form when electrode is lifted To stop welding momentarily depress output switch and out put will shut off Note If output switch is momen tarily depressed a...

Страница 30: ...hs Replace Damaged Or Unreadable Labels Replace Cracked Torch Body Repair Or Replace Cracked Cables Repair Or Replace Cracked Cables And Cords Clean And Tighten Weld Connections 6 Months Blow Out Insi...

Страница 31: ...rized Service Agent Help 2 Display Indicates a malfunction in the ther mal protection circuitry located on the left side of the unit If this display is shown contact a Factory Autho rized Service Agen...

Страница 32: ...If this display is shown have an elec trician check the input voltage Help 7 Display Indicates that the input voltage is too high and the unit has automatically shut down Operation will continue when...

Страница 33: ...f necessary or reset circuit breaker see Section 4 11 Check for proper input power connections see Section 4 11 No weld output meter display On If using remote control be sure Mode Selector switch is...

Страница 34: ...OM 180 670 Page 30 SECTION 7 ELECTRICAL DIAGRAM 239 530 B Figure 7 1 Circuit Diagram For Welding Power Source...

Страница 35: ...OM 180 670 Page 31 Notes...

Страница 36: ...LIST 802 801 D 1 2 3 26 27 28 29 30 31 14 11 36 37 38 40 47 48 49 50 51 55 56 57 58 59 22 60 61 62 4 5 6 65 14 13 7 15 17 18 19 20 22 23 24 25 32 33 34 39 41 42 13 43 44 45 46 16 21 8 9 10 11 12 35 52...

Страница 37: ...del And Serial Number 1 22 670836 Box Louver ME 175 138 2 23 Bracket Mtg Contactor Capacitor PC Board ME 192 853 1 24 PC1 670844 Circuit Card Control ME 229 961 1 PLG2 Connector Sockets ME 131 056 1 P...

Страница 38: ...el Front ME 185 732 1 56 670968 Receptacle Twlk Insul Fem ME 129 525 2 57 670976 Nameplate Order By Model And Serial Number 1 Tubing Gl Acryl 325 Order By Ft ME 070 590 1ft 670984 Kit Connection Dinse...

Страница 39: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Страница 40: ...PRINTED IN USA 2012 01 Unitor ASA Drammensveien 211 P O Box 300 Skoyen N 0212 Oslo Norway Tel 47 22 13 14 15...

Отзывы: