![Unitek BAMOCAR-PG-D3-700-900 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/unitek/bamocar-pg-d3-700-900/bamocar-pg-d3-700-900_manual_4037715033.webp)
Control connections
Version: 2020 / V3
Seite: 32
BAMOCAR-PG-D3-700-900
4
Control connections
4.1
Digital inputs
The enable input (FRG/RUN) and the input for the rotating field enable (RFE) are fixed, they cannot be
programmed.
Without the enable FRG/RUN the servo-drive is electronically disabled (no PWM pulses).
Without the rotating field enable RFE the rotating field of the output stage is additionally disabled
(2nd disable channel).
The drive is free of torque (no holding torque).
The other 4 digital inputs are freely programmable.
The inputs LMT1 (X1:15) and LMT2 (X1:16) are preferably to be used as inputs of the output stage
switch.
Input
Connector
Function
State
RFE
X1:19
Rotor enable
fixed
FRG/RUN
X1:14
Enable
fixed
END1/LMT1
X1:15
Output stage switch 1
programmable
END2/LMT2
X1:16
Output stage switch 2
programmable
DIN1
X1:17
Digital input 1
programmable
DIN2
X1:18
Digital input 2
programmable
The enable (FRG X1:14) must not be initiated before the auxiliary voltage (12..24 V)
and the power voltage have been switched on.
External power supply for the inputs and outputs
+12..+24 V for the logic voltage
GNDE logic ground
Input voltage
Level ON
+10..+30 V
Level OFF
< +6 V
Input current
Max. 7.5 mA
Nominal
voltage / current
+24 V/6 mA
Ground reference
GNDE (X1:K)
Содержание BAMOCAR-PG-D3-700-900
Страница 20: ...Mechanical installation Version 2020 V3 Seite 19 BAMOCAR PG D3 700 900 2 2 Dimensions BAMOCAR PG D3 700 900...
Страница 23: ...Electrical installation Version 2020 V3 Seite 22 BAMOCAR PG D3 700 900 3 2 Circuit diagramm...
Страница 24: ...Electrical installation Version 2020 V3 Seite 23 BAMOCAR PG D3 700 900...
Страница 25: ...Electrical installation Version 2020 V3 Seite 24 BAMOCAR PG D3 700 900 3 3 Connection diagramm...