Description 

 

The TX+DWS Door/Window Sensor is intended for installation on doors, 
windows, and other objects that open and close. The sensor transmits signals 
to the control panel when a magnet mounted near the sensor is moved away 
from or closer to the sensor.  
 
The TX+DWS features the TX+ Encryption protocol which provides encrypted 
wireless communication to select Interlogix control panels. Please refer to your 
panel’s installation instructions to see if it is TX+ Encrypted capable.  
 
The TX+DWS also utilizes the standard ITI-319 protocol which is compatible 
with all Interlogix control panels and receivers.  

Figure 1: TX+DWS 

 

 

 

Enrollment Into TX+ Encryption Supported Panels 

 

To enroll the TX+DWS as an encrypted sensor into a panel that supports the 
TX+ Encryption protocol, follow these steps: 

1) 

Place the panel into program mode, then go to Learn Sensors menu. 
Refer to your specific alarm panel manual for details on these 
menus.   

2) 

Once the Learn Sensors mode has been activated, remove the 
battery pull tab to auto-enroll the device. Then select the appropriate 
sensor group and number. Refer to your specific alarm panel manual 
for details on the different sensor groups. 

3) 

If the panel does not respond upon removing the battery pull tab, exit 
the Learn Sensors mode and then remove the front sensor housing 
and transmitter from the back housing by inserting a small flat head 
screwdriver into the slot at the top of the sensor and pressing on the 
tab. Remove the batteries from the sensor.  

4) 

With the batteries removed, return back to the panel and activate the 
Learn Sensors mode again. With Learn Sensors mode activated, re-
insert the batteries (paying close attention to the battery polarity 
indicators) to auto-enroll the device.  

Note: Utilization of the TX+ Encrypted protocol is only compatible with 
select Interlogix control panels. When enrolled into a panel that is TX+ 
Encrypted capable, the enrollment menu screen may indicate “TX+ 
Encrypted” to verify that the sensor is communicating to the panel via the 
encrypted protocol. Please refer to your panel’s installation instructions 
to verify that the panel supports TX+ Encrypted capability.   

 

Enrollment into Non TX+ Encryption Supported Panels (ITI-
319 Protocol) 

 

To enroll the TX+DWS into a panel utilizing the standard ITI-319 protocol, 
follow these steps: 

1) 

First remove the battery pull tabs from the device. 

2) 

After the pull tabs have been removed, place the panel into program 
mode, then go to Learn Sensors menu. Refer to your specific alarm 
panel manual for details on these menus.   

3) 

Once the Learn Sensors mode has been activated, remove the front 
sensor housing and transmitter from the back housing by inserting a 
small flat head screwdriver into the slot at the top of the sensor and 
pressing on the tab. This will activate the tamper switch which will 
auto-enroll the device. Then select the appropriate sensor group and 
number. Refer to your specific alarm panel manual for details on the 
different sensor groups. 

4) 

If the panel does not respond upon tampering the device, replace 
and then remove the cover again to tamper the sensor another time. 
Repeat until the panel responds, and then continue to selecting the 
appropriate sensor group and number.  

 

Mounting 

Included with this device is double sided tape for the transmitter and magnet, 
as well as screws if a more secure method of mounting is preferred. Choose a 
suitable location for the sensor by following the procedure in the section 
“Sensor Testing” ensuring desired signal strength is achieved. Note that it is 
recommended the transmitter be installed on the stationary or non-moving part 
of the installation (frame) and the magnet installed on the moving object (door).  

Where possible, install sensors within 100 ft. (30 m) of the panel. While a 
transmitter may have an open-air range of 500 ft. (150 m) or more, the 
environment at the installation site may have a significant effect on operational 
range. Changing a sensor location may improve wireless communication. 

For reliable bonding with the provided double sided tape, ensure the surface is 
clean and dry. Apply the tape to the backside of the sensor, and then to the 
desired location. Apply firm pressure for several seconds. When mounting with 
double sided tape, ensure temperatures are above 50°F and will remain above 
50°F for at least 24 hours to ensure proper bond. After 24 hours, the bond will 
hold at lower temperatures. 

Sensor Testing  

The sensor test verifies proper communication between the sensor and the 
panel/receiver. The sensor should be tested prior to permanent installation, as 
well as weekly. To test the sensor, refer to the specific panel/receiver 
documentation and do the following: 

1) 

Put the panel/receiver into sensor test mode 

2) 

Open the door/window the sensor is installed on 

– the sensor will 

then transmit a signal 

3) 

Listen for the siren beeps to determine the appropriate response.  

 

 

 

 

Отзывы: