background image

OWNERS MANUAL

Models B2350 and B2350B

Wonderluxe

THERMOSTAT CONTROLLED DUAL FUEL CIRCULATOR SERIES

SAFETY NOTICE:

If this heater is not properly installed, a house fire may result.

To reduce the risk of fire, follow the installation instructions.

Contact local building or fire officials about permits, restrictions 

and inspection requirements in your area.

• ASSEMBLY
• INSTALLATION
• OPERATION
• REPAIR PARTS

Tested To:

UL 1482 - 06 &
ULC S627-00

851884

United States Stove Company

227 Industrial Park Rd.

P.O.Box 151

South Pittsburg, TN 37380

(423) 837-2100

www.USSTOVE.com

CAUTION:

Please read this entire manual before you install and use your 

new room heater. Failure to follow instructions may result in prop-

erty damage, bodily injury, or even death.

DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER

C

C

S

S

S

S

U

U

COMPANY

UN

ITE

D STATES STOV

E

Ê

É

Fold Here

Fold Here

Place

StamP

Here

United States Stove company

P.O. Box 151

South Pittsburg, tN 37380

CUT

 HERE

CUT

 HERE

Содержание Wonderluxe B2350B

Страница 1: ...OPERATION REPAIR PARTS Tested To UL 1482 06 ULC S627 00 851884 United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 www USSTOVE com CAUTION Please read...

Страница 2: ...in good repair Have the chimney inspected by the Fire Department or a qualified inspector such as a Chimney sweep Your insurance company may be able to recommend a qualified inspector 6 Inspect chimn...

Страница 3: ...ector However therearelimits tohowclose theheater and chimney connector can be installed to combustible surfaces protected by a clearance reduction system Acorrectlyinstalledclearancereductionsystem p...

Страница 4: ...ou have the clearances shown from the heater and the connector pipe to combustible surfaces If you have a solid brick or stone wall behind your heater you can place the heater as close as you wish to...

Страница 5: ...metal screws and seal each joint with furnace cement The pipe must be short and straight All sections installed horizontally must slope at least 1 4 inch per foot with the upper end of the section to...

Страница 6: ...e house Therefore the gas which circulates will cool more slowly thus reducing the build up of creosote and the risk of chimney fires 4 The draft caused by the tendency for hot air to rise will be inc...

Страница 7: ...age firestops where needed FACTORY BUILT CHIMNEY insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufacturer The chimney must be the r...

Страница 8: ...ace with refractory mortar The thimble should be surrounded on all sides with 8 inches of brickwork solid masonry units or 24 inches of stone Install the stovepipe as far as possible into the thimble...

Страница 9: ...onjunction with its height or some other factor of an indeterminate cause In this event you should install a barometric draft regulator Such installation will preclude any over firing and or any hazar...

Страница 10: ...x The first flames will be long and generally orange or yellow and produce quite a bit of smoke As the gases burn off the flames become shorter change color and produce less smoke Once the fire is WEL...

Страница 11: ...n 2 5 16 and 4 3 8 Note that it is important to the life of your stove to buy coal which has been sized and cleaned Cleaning insures removal of rocks and other materials DO NOT burn coke charcoal high...

Страница 12: ...r speed reduces 3 Rotate the knob counter clock wise to turn OFF A B C D Follow these instructions to operate you unit safely when operating the feed door NOTE DURING OPENING AND CLOSING OF THE FEED A...

Отзывы: