background image

6

© 2021 United States Stove Company

INSTALLATION

SECURING APPLIANCE TO THE FLOOR

Use the designated holes to secure the unit to the floor.

MOBILE HOME

MOUNTING BOLT HOLES

WARNING! DO NOT INSTALL IN SLEEPING ROOM.

CAUTION! THE STRUCTURAL INTEGRITY OF THE 

MOBILE HOME FLOOR, WALL, AND CEILING/ROOF 

MUST BE MAINTAINED.

WHEN INSTALLED IN A MOBILE HOME, THE STOVE 

MUST BE GROUNDED DIRECTLY TO THE STEEL 

CHASSIS AND BOLTED TO THE FLOOR.

In addition to the previously detailed installation 

requirements, mobile home installations must meet the 

following requirements:

• 

This stove must be securely fastened to the floor of the 

mobile home through the two holes in the rear of the 

stove using two, 1/4” lag bolts that are long enough to 

go through both a hearth pad, if used, and the floor of 

the home.

•  The heater must be electrically grounded to the steel 

chassis of the mobile home with 8 GA copper wire using 

a serrated or star washer to penetrate paint or protective 

coating to ensure grounding.

• 

Vent must be 3 or 4-inch “PL” Vent and must extend a 

minimum  or  36”  (914  mm)  above  the  roof  line  of  the 

mobile  home  and  must  be  installed  using  a  certified 

ceiling fire stop and rain cap.

•  When moving your mobile home, all exterior venting must 

be removed while the mobile home is being relocated. 

After  relocation,  all  venting  must  be  reinstalled  and 

securely fastened.

•  Outside air is mandatory for mobile home installation. 

See  Outside  Air  Supply  section  and  your  dealer  for 

purchasing.

• 

Check with your local building officials as other codes 

may apply.

VENTING REQUIREMENTS

WARNING:

•  INSTALL VENT AT CLEARANCES SPECIFIED BY THE 

VENT MANUFACTURER.

•  DO NOT CONNECT THE PELLET VENT TO A VENT 

SERVING ANY OTHER APPLIANCE OR STOVE.

•  DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST 

VENTING SYSTEM OF THIS UNIT.

The following installation guidelines must be followed 

to ensure conformity with both the safety listing of this 

stove and to local building codes. Do not use makeshift 

methods or compromise in the installation.

IMPORTANT:

THIS UNIT IS EQUIPPED WITH A NEGATIVE DRAFT 

SYSTEM THAT PULLS AIR THROUGH THE BURN POT 

AND PUSHES THE EXHAUST OUT OF THE DWELLING. 

IF THIS UNIT IS CONNECTED TO A FLUE SYSTEM 

OTHER THAN THE WAY EXPLAINED IN THIS MANUAL, 

IT WILL NOT FUNCTION PROPERLY.

MAXIMUM VENTING DISTANCE

Installation MUST  include  at  least 3-feet of  vertical pipe 

outside the home. This will create some natural draft to 

reduce the possibility of smoke or odor during appliance 

shutdown and keep exhaust from causing a nuisance or 

hazard by exposing people or shrubs to high temperatures. 

The maximum recommend vertical venting height is 12-

feet for 3-inch type “PL” vent. Total length of horizontal vent 

must not exceed 4-feet. This could cause back pressure. 

Use no more than 180 degrees of elbows (two 90-degree 

elbows, or two 45-degree and one 90-degree elbow, etc.) 

to maintain adequate draft.

IMPORTANCE OF PROPER DRAFT

Draft is the force which moves air from the appliance up 

through the chimney. The amount of draft in your chimney 

depends on the length of the chimney, local geography, 

nearby obstructions and other factors. Too much draft 

may cause excessive temperatures in the appliance. 

Inadequate draft may cause backpuffing into the room and 

‘plugging’ of the chimney. Inadequate draft will cause the 

appliance to leak smoke into the room through appliance 

and chimney connector joints. An uncontrollable burn or 

excessive temperature indicates excessive draft. Take into 

account the chimney’s location to ensure it is not too close 

to neighbors or in a valley which may cause unhealthy or 

nuisance conditions.

Содержание VOGELZANG VG5770

Страница 1: ...ding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or us...

Страница 2: ...stallation and operation of the Vogelzang VG5770 wood heater This heater meets the 2020 US Environmental Protection Agency s wood pellet emissions limits for wood heaters sold after May 15 2020 Under...

Страница 3: ...________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Instal...

Страница 4: ...NG SMOKE DETECTOR MUST BE INSTALLED IN THE SAME ROOM AS THIS PRODUCT INSTALL A SMOKE DETECTOR ON EACH FLOOR OF YOUR HOME INCASE OF ACCIDENTAL FIRE FROM ANY CAUSE IT CAN PROVIDE TIME FOR ESCAPE THE SMO...

Страница 5: ...ions Any reduction in clearance to combustibles may only be done by means approved by a regulatory authority E F G E F G H H H H TABLE 1 CLEARANCES in mm PARALLEL E Back wall to unit 3 76 F Sidewall t...

Страница 6: ...E OR STOVE DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT The following installation guidelines must be followed to ensure conformity with both the safety listing of this stov...

Страница 7: ...aled with silicone or other means to maintain the vapor barrier between the exterior and the interior of the home Vent surfaces can get hot enough to cause burns if touched by children Noncombustible...

Страница 8: ...bove the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this...

Страница 9: ...rolled with a Thermostat Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat...

Страница 10: ...n diameter and not over 1 long Longer or thicker pellets sometimes bridge the auger flights which prevents proper pellet feed Burning wood in forms other than pellets is not permitted It will violate...

Страница 11: ...ass door and prevent the rapid buildup of creosote inside your stove and chimney You should adjust the damper based on the fire s appearance A low reddish dirty fire can be improved by turning the dam...

Страница 12: ...before restarting your stove On other units the thermodisc has no reset button and will reset itself once the stove has cooled The manufacturer recommends that you call your dealer if this occurs as...

Страница 13: ...fessionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combusti...

Страница 14: ...s HOT Do not attempt to operate the unit with broken glass Replacement glass may be purchased from your U S Stove dealer If glass is broken follow these removal procedures 1 Once the heater has cooled...

Страница 15: ...ail parts usstove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered B...

Страница 16: ...lower heat setting Fuel other than wood pellets is being burned in the stove This pellet stove is designed and tested to use wood pellets Check for signs of fuel other than wood pellets No other type...

Страница 17: ...turn the shaft is jammed on something If the motor will not turn the motor is bad The Proof of Fire POF thermodisc has malfunctioned Temporarily bypass the POF thermodisc by disconnecting the two wir...

Страница 18: ...can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in...

Страница 19: ...joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been properly sealed with the same RTV The gasket on the combustion blower has gone bad I...

Страница 20: ...connector Bad control board If the fuse is good the wires and connectors check out good and the high limit switch did not trip test for power going to the auger motor If there is not a full current go...

Страница 21: ...2021 United States Stove Company 21 CORRECT WRONG ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN WIRING DIAGRAM...

Страница 22: ...22 2021 United States Stove Company 1 2 3 4 8 9 15 17 19 34 20 21 22 23 27 28 29 30 35 36 37 38 40 41 24 25 5 6 7 43 18 26 33 14 1 16 18 39 42 12 13 31 32 REPAIR PARTS...

Страница 23: ...on 1 32 83537 Hose Clamp 1 33 88176 Insulating Blanket 1 34 88177 Gasket Ash Clean out 2 35 88175 Gasket T disc 2 36 80601 T Disc Room Air 1 37 88167 Gasket Room Blower 1 38 80604 Igniter 1 39 80622 R...

Страница 24: ..._ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No __________________________...

Страница 25: ...______________ Service de 07 Date _______________________ Nom de l ing nieur __________________________________ N de licence _______________________________________ Compagnie _________________________...

Страница 26: ...Couverture isolante 1 34 88177 Joint Ash Clean out 2 35 88175 Joint T disque 2 36 80601 T Disc Chambre Air 1 37 88167 Joint Chambre Blower 1 38 80604 Igniter 1 39 80622 Chambre Blower 1 40 80549 Inter...

Страница 27: ...22 2021 United States Stove Company 1 2 3 4 8 9 15 17 19 34 20 21 22 23 27 28 29 30 35 36 37 38 40 41 24 25 5 6 7 43 18 26 33 14 1 16 18 39 42 12 13 31 32 SCH MA DES PI CES...

Страница 28: ...2021 United States Stove Company 21 CORRECT FAUX ASSUREZ VOUS QUE LES FILS SONT CONNECT S AUX DEUX BROCHES INF RIEURES DE L INTERRUPTEUR DE LA TR MIE COMME ILLUSTR SCH MA DE C BLAGE...

Страница 29: ...t bien fix e la tige du registre d admission Lorsqu on d place la tige du registre la plaque doit se d placer avec elle Blocage du conduit d admission d air Inspecter visuellement le conduit d admissi...

Страница 30: ...re l origine du blocage Fil d branch ou connecteur desserr V rifiez tous les fils et connecteurs branch s sur le moteur de tari re l interrupteur de surchauffe et le connecteur Molex Tableau de comman...

Страница 31: ...tions possibles D branchez le po le avant toute chose quand c est possible Il y a une fuite dans le syst me de conduit d vacuation Inspectez tous les raccords de tuyaux d vacuation Assurez vous qu ils...

Страница 32: ...re L arbre de la tari re est coinc Commencez par vider la tr mie Puis retirez le moteur de la tari re en retirant la goupille de la tari re Retirez la plaque d inspection de l arbre de la tari re dans...

Страница 33: ...ue chose Si le moteur ne tourne pas il est d fectueux Le thermodisque de d tection de feu POF a mal fonctionn Contournez temporairement le thermodisque POF en d branchant les deux fils et en les racco...

Страница 34: ...hauffe potentielle Dans ce cas essayez d utiliser un r glage de chauffage inf rieur Un autre combustible que les granul s de bois est br l dans le po le Ce po le granul s a t con u et test pour br ler...

Страница 35: ...orrectement tout le verre cass Seul le verre c ramique haute temp rature de la taille et de l paisseur appropri es peut tre utilis NE PAS substituer les mat riaux alternatifs pour le verre Contactez v...

Страница 36: ...ner le flux normal d vacuation Elles doivent donc tre p riodiquement limin es ENL VEMENT ET LIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE PO LE REFROIDIR AVANT D EFFECTUER TOUT ENTRETIEN OU NETTOYAG...

Страница 37: ...a refroidi Le fabricant vous recommande de vous adresser au revendeur si cela se produit car cela peut indiquer un probl me plus grave Il peut s av rer n cessaire d appeler le service de r paration 2...

Страница 38: ...diff rentes marques de granul s et des d bits d alimentation des granul s Il vous permet d am liorer l efficacit de votre po le Fournir un air de combustion correct r duira la fr quence de nettoyage...

Страница 39: ...er les ailettes de la tari re ce qui emp che une bonne alimentation en granul s Il est interdit de br ler du bois sous d autres formes que des granul s Il s agirait d une violation des codes du b time...

Страница 40: ...ement du po le peut tre Manuel ou command par un Thermostat Des diodes distinctes gauche de l cran deux chiffres indiquent le mode de fonctionnement Manuel ou T stat Le po le doit tre en mode de fonct...

Страница 41: ...a neige est abondante il est recommand que la sortie de l installation se trouve plus de 3 pi 0 91 m pour chapper la ligne de cong re Cette m me installation peut tre utilis e si le po le se trouve so...

Страница 42: ...0 50 Tous les raccords du syst me d vacuation doivent tre fix s par au moins 3 vis et scell s avec une colle de silicone RTV haute temp rature pour les rendre tanches l air La zone o le conduit d vacu...

Страница 43: ...CIFI S PAR LE FABRICANT D VACUATIONS NE RELIEZ PAS L VACUATION POUR PO LE GRANUL S UNE VACUATION UTILIS E POUR UN AUTRE APPAREIL OU UN AUTRE PO LE N INSTALLEZ PAS DE REGISTRE DE TIRAGE SUR LE SYST ME...

Страница 44: ...combustibles ne peut tre effectu e que par des moyens approuv s par une autorit r glementaire E F G E F G H H H H TABLE 1 CLEARANCES po mm Parall le E Mur arri re l appareil 3 76 F Mur lat ral au con...

Страница 45: ...N IMPORTE QUELLE CAUSE CE DISPOSITIF PEUT LAISSER LE TEMPS DE S CHAPPER LE D TECTEUR DE FUM E DOIT TRE INSTALL AU MOINS 15 PIEDS 4 57 M DE L APPAREIL AFIN D VITER QU IL NE SE D CLENCHE INUTILEMENT LOR...

Страница 46: ...date d inspection du syst me de ventilation existant _______________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment au...

Страница 47: ...le fonctionnement des appareils de chauffage au bois Vogelzang VG5770 Ce po le respecte les limites d mission de pellets de bois impos es par la US Environmental Protection Agency en 2020 pour les po...

Страница 48: ...les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser...

Отзывы: