background image

-6-

SPECIAL MOBILE HOME REQUIREMENTS (APPROVED FOR USE IN MOBILE HOMES (USA ONLY)

WARNING - DO NOT INSTALL IN A SLEEPING ROOM.

CAUTION - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.

In addition to the previously detailed installation requirements, mobile home installations must meet the following 

requirements:

• 

The space heater is to be connected to a factory-built chimney conforming to  UL 103, therefore it must be a 

Type HT (2100°F).

• 

The heater must be permanently attached to the floor. 

• 

The heater must be electrically grounded to the steel chassis of the mobile home with 8 ga copper wire using 

a serrated or star washer to penetrate paint or protective coating to ensure grounding.

• 

When  moving  your  mobile  home,  all  exterior  venting  must  be  removed  while  the  mobile  home  is  being 

relocated. After relocation, all venting must be reinstalled and securely fastened.

• 

Outside air is mandatory for mobile home installation. See your dealer for purchasing.

• 

Check with your local building officials as other codes may apply.

• 

Only use the specified components listed in this manual for this unit. The use of components that are not meant 

for this unit can cause unsafe conditions.

COMBUSTION AIR ASSEMBLY INSTRUCTIONS (REQUIRED FOR MOBILE HOME INSTALLATIONS)

This appliance requires a source of combustion air when installed in a mobile home.

If the building this unit is being installed in is of tight construction or has negative pressure problems, an outside 

source of air is needed. Below is a list of possible indicators that a source of outside combustion air may be 

required.

• 

The stove does not draw steadily, smoke rollout occurs, wood burns poorly, or back-drafts occur whether or 

not there is combustion present.

• 

Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances, smell, do not operate 

properly, suffer smoke roll-out when opened, or back-drafts occur whether or not there is combustion present.

• 

Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.

• 

The house is equipped with a well-sealed vapor barrier and tight fitting windows and/or has any powered 

devices that exhaust house air.

• 

There is excessive condensation on windows in the winter.

• 

A ventilation system is installed in the house.

If an outside air intake is required, you may purchase a standard 4” dryer vent kit from your local hardware supply 

store and install it on the rear of the appliance.

When using a dryer venting kit, the outlet cover must be of a design that 

DOES NOT

 close by means of a flap or 

trap door. You must purchase a style that allows a continuous in-flow of air and that has a rodent screen. This 

adapter can be purchased from your dealer.

4FAK INSTALLATION

Follow the manufacturer’s installation 

instructions  for  attaching  the  dryer 

vent  kit  to  the  home.  Then,  attach 

it to the adapter on the combustion 

air  inlet  on  the  back  of  the  unit  as 

shown.

“Dryer  Venting  Kit” 

Installation

Slide  the  hose  clamp  over  the  aluminium  flex 

pipe. Then slide the flex pipe over the air intake 

tube of the stove. Next tighten the hose clamp 

over the end of the aluminium flex hose.

SECURING APPLIANCE TO THE FLOOR

Use the designated holes to secure the unit to the floor as shown.

Содержание VOGELZANG VG4020

Страница 1: ...015 and Certified to ULC S627 00 REV1 Room Heater Solid Fuel Type Also For Use In Mobile Homes USA Only SAVE THESE INSTRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM TH...

Страница 2: ...epth 11 3 8 x 24 3 4 289 mm x 629 mm Volume Cubic Feet 2 32 ft Door Opening Width x Height 10 x 11 3 8 854 mm x 289 mm Note Register your product on line at www usstove com Save your receipt with your...

Страница 3: ...knob assembly 1 Remove the machine screw and the door knob 2 Place the knob on the outside of the cabinet door re install the machine screw and tighten Be careful not to strip out the threads in the...

Страница 4: ...ire department Do not connect to any air distribution duct or system A source of fresh air into the room or space heated shall be provided when required POSITIONING THE STOVE It is very important to p...

Страница 5: ...etween the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe The chimney connector must not pass through an attic or roof space closet or similar concealed space a floo...

Страница 6: ...st of possible indicators that a source of outside combustion air may be required The stove does not draw steadily smoke rollout occurs wood burns poorly or back drafts occur whether or not there is c...

Страница 7: ...controllable burn or excessive temperature indicates excessive draft 3 screws Flow Direction of Flue Gases Install crimped end towards stove Male Part Downwards 1 4 slope per foot CHIMNEY Take into ac...

Страница 8: ...Clearance to Combustibles Combustible Wall Floor Protector To Stove Storm Collar Flashing Listed Chimney Attic Insulation Sheild Specified Clearance Chimney Connector Combustible Ceiling Joists To Sto...

Страница 9: ...ey connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fib...

Страница 10: ...ns Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wo...

Страница 11: ...s 6 Materials containing asbestos 7 Construction or demolition debris 8 Railroad ties or pressure treated wood 9 Manure or animal remains 10 Salt water driftwood or other previously salt water saturat...

Страница 12: ...uired to properly burn coal or coal products Do not elevate the fire using grates or irons Build the fire directly on the firebrick FUELING INSTRUCTIONS This wood stove has been certified by the US EP...

Страница 13: ...tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency Any damage or deterioration of these tubes may reduce the efficiency of combustio...

Страница 14: ...between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREVENT CREOSOTE BUILD UP Al...

Страница 15: ...posure It is recommended that you use both smoke and CO monitors in areas having the potential to generate CO GASKET CARE This unit s door uses a 1 diameter rope gasket It is recommended that you chan...

Страница 16: ...e Collar Gasket 1 6 891492 Blower Assembly B36 1 7 25598 Blower Mounting Box 1 8 29329 Smoke Curtain 1 9 610508 Right Side Casing 1 10 67969 Cabinet Door Assy 1 11 67444 Ash Pan Weldment 1 12 67859 Ba...

Страница 17: ...2 5 ft 8 40764 Cast Door 1 3 5 8 1 2 7 6 4 2 1 3 5 4 6 7 8 9 10 11 14 13 15 16 18 17 12 Key Part Description Qty 1 88336 Insulation Blanket 1 2 88335 Baffle Board 2 3 29437 Tube Retainer 1 4 29438 Ba...

Страница 18: ...ame _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ______________________________________ S...

Страница 19: ...ice fiable et efficace de votre appareil de chauffage et vous permettre de commander correctement les pi ces de rechange Conservez ce manuel dans un endroit s r pour r f rence future Lors de l criture...

Страница 20: ...12 67859 Soudure De Base 1 13 22110 Bouclier Thermique 1 14 25550 Amortisseur De Tirage H pin 1 15 27469 Bras Amortisseur 1 16 610987 Ensemble De Bo te De Distribution D air 1 17 89687 Bouton De Ther...

Страница 21: ...16 Pi ces De Rechange 1 2 3 4 6 7 9 10 11 12 13 14 15 16 17 19 20 21 22 23 18 24 25 26 27 5 8...

Страница 22: ...METTEZ PAS AU CORDON D ALIMENTATION DE TOUCHER LES SURFACES CHAUDES GARDER LE CORDON D ALIMENTATION AU MOINS 12 po 30 5CM DES SURFACES DU PO LE OU DU TUYAU DANGER RISQUE D LECTROCUTION D BRANCHER LA S...

Страница 23: ...FAIRE FONCTIONNER LE PO LE LE CENDRIER PEUT DEVENIR TR S CHAUD PORTER DES GANTS POUR PR VENIR LES BLESSURES NE BR LEZ JAMAIS LE PO LE AVEC LE PI GE CENDRES OUVERT CELA POURRAIT PROVOQUER PLUS DE CUISS...

Страница 24: ...atement le registre pour r duire l alimentation en air et ralentir le feu Entretien De La Chemin e AVERTISSEMENT Les feux combustion lente pour une utilisation prolong e ou la combustion de bois vert...

Страница 25: ...br l jusqu un lit de charbon de d marrage chargez l unit avec environ 24 lb de carburant pour la premi re charge de combustion lev e Fermez la porte imm diatement Apr s la premi re charge de combusti...

Страница 26: ...Ce chauffage au bois a un taux de combustion minimum r gl la fabrication et qui ne peut tre modifi La modification de ce r glage ou une utilisation autre de ce chauffage au bois qui ne respecterait pa...

Страница 27: ...is utilis tait trop humide ou avait s ch dans de mauvaises conditions Ces probl mes peuvent tre probl mes d allumage accumulation de cr osote causant des incendies de chemin e rendement nerg tique bas...

Страница 28: ...o minimum aux mat riaux combu ibles Chemin e en ma onnerie Conduit de chemin e Doublage en argile r fractaire Conduit de raccordement D gagement minimum de 30 cm 12 po 304 8 mm des briques Le d gageme...

Страница 29: ...ment appropri avec la structure tel que recommand par le fabriquant La chemin e doit avoir la hauteur requise au dessus du toit ou d autres obstructions pour des raisons de s curit et un bon tirage Re...

Страница 30: ...e fabriqu e en usine elle doit r pondre la norme UL 103 et CAN CSA B365 par cons quent elle doit tre de type HT 2100 F Il est extr mement important qu elle soit install e conform ment aux sp cificatio...

Страница 31: ...d indicateurs possibles indiquant qu une source d air de combustion ext rieur peut tre requise Votre po le n effectue pas un tirage uniforme produit des retours de fum e ne br le pas bien le combusti...

Страница 32: ...e l avant de l appareil Le jeu entre le conduit de fum e et un mur est valable uniquement pour les parois verticales et conduit de fum e vertical Le connecteur de chemin e ne doit pas passer travers u...

Страница 33: ...ION CONSULTER VOTRE SERVICE MUNICIPAL IMMEUBLE OU D INCENDIE PROPOS DE PERMIS RESTRICTIONS ET INSTALLATIONS EXIGENCES DANS VOTRE R GION UTILISATION D TECTEUR DE FUM E DANS LA PI CE O EST INSTALL VOTRE...

Страница 34: ...a poign e de porte 2 Placez le bouton l ext rieur de la porte de l armoire r installez la vis m taux et serrez Veillez ne pas retirer les fils de la poign e FONCTIONNEMENT DE LA POIGN E ET DE LA PORTE...

Страница 35: ...construction de 2020 de la US Environmental Protection Agency pour les appareils de chauffage au bois vendus apr s le 15 mai 2020 Dans des conditions de test sp cifiques il a t d montr que cet appare...

Страница 36: ...Z DANS UN ENDROIT S R POUR R F RENCE FUTURE U S Environmental Protection Agency Certifi pour se conformer aux normes d missions de particules de 2020 AVERTISSEMENT CONCERNANT LA PROPOSITION 65 DE L TA...