Project # 23-114 Model: SP1000E
Page | 9
Test Conditions Summary
Testing conditions for all runs fell within allowable specifications of ASTM E2779 and
ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below.
Runs
Ambient (°F)
Relative
Humidity (%)
Average
Barometric
Pressure
(In. Hg.)
Preburn
Fuel
Weight
(lbs)
Test Fuel
Weight
(lbs)
Test Fuel
Moisture
(%DB)
Test Run
Time
(Min)
Pre
Post
Pre
Post
1
72
76
37.5
33.6
29.92
5.6
14.9
6.4%
360
Appliance Operation and Test Settings
The appliance was operated according to procedures as described in the Operations
Manual, found in Appendix B submitted with this report. Detailed run information can be
found in Appendix A submitted with this report.
Settings & Run Notes
Pre-Burn
Test Run
Run 1
Heat Level: 5
Air Damper: Fully Open
Maximum Segment
Heat Level: 5
Air Damper: Fully Open
Medium Segment
Heat Level: 2
Air Damper: Fully Closed
Minimum Segment
Heat Level: 1
Air Damper: Fully Closed
Содержание SP1000E
Страница 2: ...Project 23 114 Model SP1000E Page 2 Revision History 6 14 2023 Original Issue...
Страница 11: ...Project 23 114 Model SP1000E Page 11 Appliance Front Appliance Left...
Страница 12: ...Project 23 114 Model SP1000E Page 12 Appliance Right Appliance Rear...
Страница 14: ...Project 23 114 Model SP1000E Page 14 Pellet Fuel Analysis...
Страница 17: ...Project 23 114 Model SP1000E Page 17 Sealed Unit...
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 110: ...24 2023 Breckwell REPLACEMENT PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 27 14 15 16 17 18 19 20 21 32 22 23 24 29 28 30 26 25...
Страница 113: ...2023 Breckwell 27 ITEMS DEFINED...
Страница 181: ......
Страница 182: ......
Страница 183: ......
Страница 184: ......
Страница 185: ......
Страница 186: ......
Страница 187: ......
Страница 188: ......