background image

16/09/2020

www.uniteck.fr 

CO00250

I

CHARGE 

 

 

 

 

Panneaux solaires fins

Slim solar panels

Paneles solares slim

 

UNI

SUN MS 

50.12MS 

 100.12MS

 

150.12MS

 

FR

 

EN

 

ES

 

Содержание UNISUN 100.12MS

Страница 1: ...16 09 2020 www uniteck fr CO00250 ICHARGE Panneaux solaires fins Slim solar panels Paneles solares slim UNISUN MS 50 12MS 100 12MS 150 12MS FR EN ES...

Страница 2: ...n cellule ou ph nom ne de point chaud protection anti hot spot d aux zones d ombre ou masque de cellule Sa forme profil e permet moins de prise au vent et vite tout blocage de cordage pour une applica...

Страница 3: ...es sont r duites ou des personnes d nu es d exp rience ou de connaissance sauf si elles ont pu b n ficier par l interm diaire d une personne responsable de leur s curit d une surveillance ou d instruc...

Страница 4: ...ront alt r es En effet la mont e en temp rature du panneau due au manque de ventilation diminue les performances de 10 15 par rapport une installation non coll e et ventil e FIXATION Les panneaux UNIS...

Страница 5: ...ant ainsi toute surtension cellule Veuillez noter que la modification ou suppression des connectiques panneaux connecteurs bo te de jonction exclut toute prise en charge sous garantie PROTECTIONS COUR...

Страница 6: ...e En hiver 80 de la production se r partit entre 11h 15h contre 50 60 en t avec la dur e d ensoleillement plus tendue Il est donc conseill d viter toute forme d ombrage pendant cette plage horaire pou...

Страница 7: ...www uniteck fr 7 49 FR DIMENSIONS UNISUN 50 12MS UNISUN 100 12MS UNISUN 150 12MS...

Страница 8: ...as connect es Ne jamais d connecter les batteries sans avoir pr alablement d connect les panneaux Le non respect de cet ordre peut d r gler la tension de charge du r gulateur Pour plus d informations...

Страница 9: ...triques identiques puissance tension et intensit 5 V rifiez que la puissance des panneaux ne d passe pas la puissance et la tension accept es par le r gulateur de charge Connectez le r gulateur la bat...

Страница 10: ...s recommandons d utiliser le kit pr t l emploi UNICONNECT qui optimise vos performances lectriques et simplifie le montage Dans ce cas pr cis les deux panneaux 100W branch s en s rie restitueront au r...

Страница 11: ...sion voulue le branchement mixte en s rie et en parall le est le plus adapt Pour ce montage il convient de respecter les m mes indications que pour les installations en s rie et celles en parall le no...

Страница 12: ...t en phase de maintien de charge floating limitant la charge uniquement pour compenser l autod charge de la batterie de quelques mmA Le panneau reprendra sa production habituelle lorsque la batterie n...

Страница 13: ...ge de tension V DC courant continu correspondant la tension du panneau Branchez le c ble rouge au port r sistance et le noir sur COM common Reliez les c bles aux connecteurs du panneau rouge rouge noi...

Страница 14: ...aux connecteurs du panneau rouge rouge noir noir Positionnez le panneau solaire perpendiculaire au soleil R sultat La valeur affich e doit tre gale 20 l intensit en court circuit Isc respective au pa...

Страница 15: ...23 6 V 23 6 V 23 6 V Intensit en court circuit Icc Isc 2 75 A 5 5 A 8 25 A Efficacit des cellules 21 21 21 Efficacit des modules 13 23 14 49 14 02 Comportement en temp rature Temp rature de fonctionne...

Страница 16: ...ux normes harmonis es Basse tension EN 60335 1 2013 EN 60335 2 29 2004 CEM EN 55014 1 2007 EN 5514 2 1997 EN 61000 3 2 2006 EN 61000 3 3 2014 EN 62233 2008 ROHS EN 50571 2013 Date de marquage CE janvi...

Страница 17: ...rie due la manutention et au transport l usure normale des pi ces ex c bles etc En cas de d fauts retournez le produit votre distributeur en y joignant un justificatif d achat dat ticket de sortie de...

Страница 18: ...on hot spot protection due to shadow areas or cell masks Its streamlined shape reduces wind resistance and avoids any rope blockage on a boat application Light weighted and space saving UNISUN MS can...

Страница 19: ...abilities are reduced nor by people lacking experience or knowledge unless they have benefited supervision or prior instructions concerning the use of the device from a person responsible for their sa...

Страница 20: ...ered The lack of ventilation would cause a temperature rise affecting performance by a 10 to 15 compared to a well ventilated and not glued installation FIXING UNISUN MS panels can be fixed with sando...

Страница 21: ...y overvoltage cell Please note that any modification or suppression of panels connections connectors junction box excludes any coverage under warranty RETURN CURRENT PROTECTIONS UNISUN MS panels are e...

Страница 22: ...een 11am and 3pm against 50 60 in summer with its longer daylight periods It is therefore highly recommended to avoid any shadow on your solar panel during this time slot in order to optimize its dail...

Страница 23: ...www uniteck fr 23 49 EN DIMENSIONS UNISUN 100 12MS UNISUN 150 12MS UNISUN 50 12MS...

Страница 24: ...connecting the batteries Never disconnect the batteries before having first disconnected the panels Not complying to this order may disturb the regulator charge voltage For more information please ref...

Страница 25: ...st be of the same electrical characteristics power voltage and intensity 5 Check that the panels power does not go over the charge voltage accepted by your charge regulator Connect the regulator to th...

Страница 26: ...we recommend our ready to use UNICONNECT kit to optimize your electrical performances and simplify the mounting process In this case the two 100W solar panels connected in series will give the regula...

Страница 27: ...wer keeping a wanted voltage a mixed installation is the most adapted series parallel For this assembly the same instructions must be observed as for series and parallel installations given in the pre...

Страница 28: ...ntenance phase called floating phase limiting the charge only to compensate for the self discharge of the battery by a few mmA The panel will produce normally again as soon as the battery needs to be...

Страница 29: ...g to the panel voltage Connect the positive cable red to the port resistance and the negative one black to the COM port common Connect the cables to the connectors of the panel red red black black Res...

Страница 30: ...M port common Connect the cables to the panel s connectors red red black black Place the solar panel perpendicular to the sun Result The displayed value must be equivalent 20 to the intensity in short...

Страница 31: ...23 6 V 23 6 V 23 6 V Intensity in short circuit Icc Isc 2 75 A 5 5 A 8 25 A Cells efficiency 21 21 21 Modules efficiency 13 23 14 49 14 02 Behaviour under temperature Operation temperature 40 C 85 C...

Страница 32: ...y comply to the harmonized standards Low tension EN 60335 1 2013 EN 60335 2 29 2004 ECM EN 55014 1 2007 EN 5514 2 1997 EN 61000 3 2 2006 EN 61000 3 3 2014 EN 62233 2008 ROHS EN 50571 2013 CE date of t...

Страница 33: ...ing and transport Normal wear of parts ex cables etc In case of failure return the product to your distributor attaching The dated proof of purchase receipt bill An explanatory note of the failure Att...

Страница 34: ...tegido contra cualquier sobrevoltaje de celda o fen meno de punto caliente protecci n anti punto caliente debido a reas de sombra o m scara de celda Su forma aerodin mica ofrece una menor resistencia...

Страница 35: ...ensoriales mentals est n reducidas o por personas sin experiencias o conocimiento excepto si pudieron beneficiar previamente por parte de una persona responsable de su seguridad de vigilancia o de ins...

Страница 36: ...anel solar afectar su rendimiento La subida de la temperatura debida a una falta de ventilaci n disminuye las performancias de un 10 15 comparado con una instalaci n no pegada y ventilada FIJACI N Se...

Страница 37: ...toda sobretensi n de c lula Por favor note que toda modificaci n o supresi n de conexiones el ctricas de los paneles conectores cajas de conexi n cancela la garant a PROTECCIONES CORRIENTE INVERSA Lo...

Страница 38: ...En invierno el 80 de la producci n se distribuye entre 11am 3pm contra el 50 60 en verano debido a la duraci n de sol extendida As se recomienda evitar todo tipo de sombra en el panel durante este pe...

Страница 39: ...www uniteck fr 39 49 ES DIMENSIONES UNISUN 50 12MS UNISUN 100 12MS UNISUN 150 12MS...

Страница 40: ...st n conectadas Nunca desconecte las bater as sin haber previamente desconectado los paneles No respetar esta orden puede afectar la tensi n de carga del regulador Para m s informaciones referirse al...

Страница 41: ...s potencia tensi n e intensidad 5 Verifique que la potencia de los paneles no supera la potencia y la tensi n m ximas aceptadas por el regulador de carga Conecte el regulador a la bater a Conecte los...

Страница 42: ...tro kit listo para usar UNICONNECT que optimiza sus performancias el ctricas y facilita el montaje En este caso preciso los dos paneles 100W conectados en serie entregar n al regulador 200W 17 6V y 11...

Страница 43: ...na tensi n deseada la conexi n mixta en serie en paralelo es la m s adecuada Para este montaje es preciso respetar las mismas indicaciones que las de las instalaciones en serie y en paralelo mencionad...

Страница 44: ...ase de mantenimiento de carga floating limitando la carga nicamente para compensar la autodescarga de la bater a de unos mmA El panel volver a producir normalmente cuando la bater a necesite una recar...

Страница 45: ...orrespondiente a la tensi n del panel Conecte el cable rojo al porte resistancia y el negro en COM com n Conecte los cables de los conectores del panel rojo rojo negro negro Resultado El valor escrito...

Страница 46: ...l rojo rojo negro negro Ponga el panel solar perpendicular al sol Resultado El valor escrito tiene que ser equivalente 20 a la intensidad en corto circuito Isc del panel sta puede variar seg n las con...

Страница 47: ...idad en corto circuito Icc Isc 2 75 A 5 5 A 8 25 A Eficacidad de las c lulas 21 21 21 Eficacidad de los m dulos 13 23 14 49 14 02 Comportamiento en temperatura Temperatura de operaci n 40 C 85 C 40 C...

Страница 48: ...conformes con las normas harmonizadas siguientes Baja tensi n EN 60335 1 2013 EN 60335 2 29 2004 CEM EN 55014 1 2007 EN 5514 2 1997 EN 61000 3 2 2006 EN 61000 3 3 2014 EN 62233 2008 ROHS EN 50571 2013...

Страница 49: ...aci n y el transpore el desgaste normal de las piezas ej cables En caso de fallo devuelva el producto a su distribuidor junto con un comprobante de compra fechado boleto de caja factura una nota expli...