29
Copyright 2014 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
User-Specified Reread Delay
If you want to set your own length for the reread delay, scan the bar code below, then set the
delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then
scanning
Save
.
Scanner Time-Out
Scanner Time-Out powers down the scanner after the unit has been idle for the specified time.
To prevent the scanner from powering down, set this time-out to 0, or no timer. Scan
Scanner
Time-Out
, then set the time-out by scanning digits (from 0 - 999,999 ms) from the inside back
cover, then scanning
Save
.
Default = 1 ms
.
Centering
Use Centering to narrow the scanner’s field of view to make sure that when the scanner is
hand-held, it reads only those bar codes intended by the user. For instance, if multiple codes
are placed closely together, centering will insure that only the desired codes are read.
Note: To adjust centering when the scanner is in the stand, see Presentation Centering (page
25).
If a bar code is not touched by a predefined window, it will not be decoded or output by the
scanner. If centering is turned on by scanning
Centering On
, the scanner only reads codes
that pass through the centering window you specify using the
Top of Centering Window,
Bottom of Centering Window, Left
, and
Right of Centering Window
bar codes.