W A S H S E L E C T I I
Document Number:
WS21002
196
Document Title:
WSII Operations Manual
3. Door Switch
The door switch detects whether the door is open or closed. When the alarm is armed,
opening the door will set off the siren.
The door switch is connected to J18, pins 3 & 4 of the CPU Board.
Figure 38. Door Switch
4. Wiring Information
Refer to the following table and diagram for wiring the siren to the WS2 CPU board.
Table 38. Wiring Guide
From
To
Siren,
Black Wire
CPU Board
J1, Pin 4
Siren,
Red Wire
CPU Board
J19, Pin 4
CPU Board
J1, Pin 3
CPU Board
J19, Pin 3
Door Switch
COM
(White Wire)
CPU Board
J18, Pin 6
Door Switch
NO
(Orange Wire)
CPU Board
J11, Pin 2
CPU Board
J18, Pin 5
(Blue Wire)
CPU Board
J11, Pin1
Shock Sensor (either wire)
CPU Board
J12, Pin 3
Shock Sensor (either wire)
CPU Board
J12, Pin 6