![Unitary products group KEU060 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/unitary-products-group/keu060/keu060_installation-manual_4045400003.webp)
292426-YIM-A-0307
Unitary Products Group
3
NOMENCLATURE
GENERAL
These completely assembled 5, 7-1/2, 10 and 15 ton blower
units include a well insulated cabinet, a DX cooling coil with
copper tubes and aluminum fins, an expansion valve, a dis-
tributor, throwaway filters, a centrifugal blower, a blower
motor contactor and a small holding charge of refrigerant-22.
Blower motors and adjustable drives are factory-installed on
all units.
The units are shipped in the vertical position ready for field
installation. For horizontal installation, reverse the solid bot-
tom panel and the return air duct flange on the front of the
unit.
This instruction covers the installation and operation of evap-
orator blower units. For refrigerant piping installation instruc-
tions refer to document “Application Data - General Piping
Recommendations 247077 for Split System Air Conditioning
and Heat Pumps”.
SAFETY CONSIDERATIONS
Installer should pay particular attention to the words:
NOTE
,
CAUTION
, and
WARNING
. Notes are intended to clarify or
make the installation easier. Cautions are given to prevent
equipment damage. Warnings are given to alert installer that
personal injury and/or equipment damage may result if instal-
lation procedure is not handled properly.
RENEWAL PARTS
Contact your local York
®
parts distribution center for autho-
rized replacement parts for this equipment.
INSPECTION
As soon as a unit is received, it should be inspected for possi-
ble damage during transit. If damage is evident, the extent of
the damage should be noted on the carrier's freight bill. A
separate request for inspection by the carrier's agent should
be made in writing.
$
(8
3URGXFW*HQHUDWLRQ
)RXUWK*HQHUDWLRQ
.
<RUN,QGRRU6SOLW6\VWHP3URGXFW1RPHQFODWXUH
7RQ
1RPLQDO&RROLQJ
&DSDFLW\0%+
3URGXFW,GHQWLILHU
(8 56WDQG(II3LSH
3URGXFW&DWHJRU\
7RQ
9ROWDJH&RGH
+HDW7\SH HDW&DSDFLW\
$ &RROLQJ2QO\6XLWDEOHIRUILHOGLQVWDOOHGHOHFWULFKHDW
7RQ
7RQ
. $LU+DQGOHU6SOLW6\VWHP$&
Improper installation may create a condition where
the operation of the product could cause personal
injury or property damage.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property dam-
age. Refer to this manual for assistance or addi-
tional information, consult a qualified installer or
service agency.
This product must be installed in strict compliance
with the enclosed installation instructions and any
applicable local, state, and national codes including
but not limited to, building, electrical and mechanical
codes.