background image

 

- 1  -

1. INTRODUCTION 

TP series adjustable DC power supply are designed to be used in applications such as powering operational 
amplifier, push pull stages, logic circuit and definition systems where plus and minus voltages are required to 
track with an insignificant error, and in any application where three independent power supplies housed in a 
single package represent an operating convenience. 
         
The instruments consist of two identical, independently adjustable and one fixed 5V/3A DC power supplies. A 
front panel switch selects one of three modes of operation: independent, series and parallel. In the independent 
mode, the output voltage and current of each supply are controlled separately, and each supply is isolated up 
to 300V from output to chassis or output to output. In the tracking mode, both outputs are automatically 
connected in series or parallel, and the controls of the left supply adjust the magnitudes of both the positive 
and negative output voltages. Because the outputs are connected in a tracking configuration, any internal 
disturbance in the master supply (such as drift or ripple) will cause an equal percentage change in the outputs 
of both the supplies. 
         
Each power supply is a completely transistorized, well-regulated, constant voltage/constant current supply that 
will furnish full rated output voltage at the maximum output current or can be continuously adjusted throughout 
the output range. The front panel current controls can be used to establish the output current limit (overload or 
shout circuit) when the supply is used as a constant voltage source (independent or tracking modes) and the 
voltage controls can be used to establish the voltage limit (ceiling) when the supply is used as a constant 
current source(independent mode only).The supply will automatically cross over from constant voltage to 
constant current operation(current limited operation in the tracking mode) and vice versa if    the output current 
or voltage exceeds these preset limits. Each supply had its own front panel meter that can measure output 
voltage and current. One power supply may be used as a master supply controlling, one slave supplies 
furnishing various voltages or current for a system. When operated with the front panel mode switch in the 
tracking position, the instrument is automatically internally connected in auto-tracking configuration. 
 
Another feature of this instrument is its output ON/OFF key. 
a. For model PS-303DU/305DU, it is only the key to cut off or resume the output as other similar instrument. 
b. For model PS-2303/2305, it is not only the key to cut off or resume the output, but also be endowed with a 
new function which its kindred has not. Also in this way, an over current by any unknown load can be avoided. 
So the new function of the key is a safety design. Especially this feature is very important to the student use. 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PS-2303

Страница 1: ...Multi channel DC Power Supply PS 303DU 305DU 3010DU 6005DU PS 2303 2305 Operation Manual V1 0 BENCHTOP INSTRUMENT...

Страница 2: ...ear Panel Control 8 5 OPERATION INSTRUCTIONS 9 5 1 Precaution 9 5 2 Setting Current Limit 9 5 3 Constant Voltage Constant Current Characteristic 9 5 4 Operation Mode 10 5 4 1 Independent Operation 10...

Страница 3: ...at the maximum output current or can be continuously adjusted throughout the output range The front panel current controls can be used to establish the output current limit overload or shout circuit...

Страница 4: ...05DU 0 60V x2 0 5A x2 Built in 16 Dimensions PS 3010DU 6005DU 255Wx155Hx460D mm PS 303DU 305DU 2303 2305 255Wx155Hx330D mm 3 SPECIFICATIONS 3 1 Operation Mode 1 Independent Two independent outputs and...

Страница 5: ...0mV Fixed output Output voltage 5V 0 25V Output current 3A Load regulation 25mV 110 220VAC rated input Ripple noise 2mVrms 5Hz 1MHz Display Voltmeter 3 digits 0 4 LED display Ammeter 3 digits 0 4 LED...

Страница 6: ...4 Fig 4 2 b PS 2303 2305 Front panel Fig 4 2 c PS 3010DU 6005DU Front panel...

Страница 7: ...5 Fig 4 3 d PS 303DU 305DU Rear panel Fig 4 4 e PS 2303 2305 Rear panel...

Страница 8: ...6 Fig 4 5 f PS 3010DU 6005DU Rear panel Fig 4 6...

Страница 9: ...when the MASTER supply is in the constant current operation 13 C C indicator Lights when the SLAVE supply is in the constant current operation Also lights when the TRACKING PARALLEL mode is selected 1...

Страница 10: ...tput terminal for 5V supply 24 Output terminal Negative polarity output terminal for 5V supply 29 Output indicator Lights when switch is engaged in 30 Output ON OFF switch DC power supply output when...

Страница 11: ...efore adding load adjust the voltage knob to the minimum value then turn on the instrument Next turn the voltage current adjustment knob to set targeted values 3 Output voltage overshoot Voltage betwe...

Страница 12: ...ry will place a heavy load on the supply and it will operate in the constant current mode which may be adjusted for a 1 amp charging rate As the battery becomes charged and its voltage approaches 13 8...

Страница 13: ...double the displayed value For example if the MASTER display is set for voltage metering and the SLAVE display for current metering the output voltage across the MASTER positive red terminal and the S...

Страница 14: ...nly the MASTER output terminals are used for parallel tracking operation In the parallel tracking mode the SLAVE supply output voltage and current are tracking the MASTER supply output voltage and cur...

Страница 15: ...correct this situation the load on the supply must be decreased so that no more than 3 amps of current are sucked 6 MAINTENANCE WARNING The following instructions are for use by qualified personnel on...

Страница 16: ...Make sure the power cord is unplugged 2 Change the AC select switch to the desired line voltage position 3 A change in line voltage may also require a corresponding change of fuse value Install the c...