Installation Manual 201.1

 

SolarMount

®

 Top Mounting

10 year limited Product Warranty, 5 year limited Finish Warranty

UniRac, Inc., warrants to the original purchaser 
(“Purchaser”) of product(s) that it manufactures 
(“Product”) at the original installation site that 
the Product shall be free from defects in material 
and workmanship for a period of ten (10) years, 
except for the anodized fi nish, which fi nish 
shall be free from visible peeling, or cracking or 
chalking under normal atmospheric conditions 
for a period of fi ve (5) years, from the earlier 
of 1) the date the installation of the Product is 
completed, or 2) 30 days after the purchase of 
the Product by the original Purchaser (“Finish 
Warranty”).

The Finish Warranty does not apply to any 
foreign residue deposited on the fi nish.  All 
installations in corrosive atmospheric conditions 
are excluded. The Finish Warranty is VOID if 

the practices specifi ed by AAMA 609 & 610-02 
– “Cleaning and Maintenance for Architecturally 
Finished Aluminum” (www.aamanet.org) are not 
followed by Purchaser. This Warranty does not 
cover damage to the Product that occurs during 
its shipment, storage, or installation.

This Warranty shall be VOID if installation of 
the Product is not performed in accordance 
with UniRac’s written installation instructions, 
or if the Product has been modifi ed, repaired, 
or reworked in a manner not previously 
authorized by UniRac IN WRITING, or if the 
Product is installed in an environment for which 
it was not designed. UniRac shall not be liable 
for consequential, contingent or incidental 
damages arising out of the use of the Product by 
Purchaser under any circumstances.

If within the specifi ed Warranty periods the 
Product shall be reasonably proven to be 
defective, then UniRac shall repair or replace 
the defective Product, or any part thereof, 
in UniRac’s sole discretion. Such repair or 
replacement shall completely satisfy and 
discharge all of UniRac’s liability with respect to 
this limited Warranty. Under no circumstances 
shall UniRac be liable for special, indirect or 
consequential damages arising out of or related 
to use by Purchaser of the Product.

Manufacturers of related items, such as PV 
modules and fl ashings, may provide written 
warranties of their own. UniRac’s limited 
Warranty covers only its Product, and not any 
related items.

Installer responsibility

Figure 4. Rails may be placed parallel or perpendicular to rafters.

The installer is solely responsible for:

•  Complying with all applicable local or national 

building codes, including any that may supercede 
this manual;

•  Ensuring that UniRac and other products are ap-

propriate for the particular installation and the 
installation environment;

•  Ensuring that the roof, its rafters, connections, 

and other structural support members can sup-
port the array under building live load conditions.

•  Using only UniRac parts and installer-supplied 

parts as specifi ed by UniRac (substitution of parts 
may void the warranty);

•  Ensuring that lag screws have adequate pullout 

strength and shear capacities as installed;

•  Maintaining the waterproof integrity of the roof, 

including selection of appropriate fl ashing; and

•  Ensuring safe installation of all electrical aspects of 

the PV array.

High-pro

fi

 le 

mode

Low-pro

fi

 le 

mode

Lower roof edge

Laying out
the  in stal la tion  area

The installation can be laid out with rails 
parallel to the rafters (high-profi le mode) 
or  per pen dic u lar  to  the  rafters  (low-profi le 
mode). Note that Solar Mount rails make ex-
cellent straight edges for doing layouts. Center 
the installation area over the rafters as much 
as possible.  

Leave enough room to safely move around the 
array during installation. 

The width  of the installation area is equal to 
the length of one module.

The length  of the installation area is equal to:

•  the total width of the mod ules,

•  plus  1 inch for each space be tween 

modules (for mid-clamp),

•  plus 3 inches (1½ inches for each set 

of end clamps).

Содержание SolarMount

Страница 1: ...ng 3 8 flange Rail length inches rails L feet bolts nuts 48 106 2 4 4 4 120 180 2 6 6 6 192 216 2 8 8 8 226 288 w splice 2 10 10 10 300 336 w splice 2 12 12 12 348 408 w splice 2 14 14 14 420 432 w splice 2 16 16 16 Top Mounting Clamp Sets Sizes A F G H and J Modules End Mid module x 5 8 flange per row clamps clamps T bolts safety bolts nuts 2 4 2 6 2 8 3 4 4 8 2 10 4 4 6 10 2 12 5 4 8 12 2 14 6 4 1...

Страница 2: ...or replacement shall completely satisfy and discharge all of UniRac s liability with respect to this limited Warranty Under no circumstances shall UniRac be liable for special indirect or consequential damages arising out of or related to use by Purchaser of the Product Manufacturers of related items such as PV modules and flashings may provide written warranties of their own UniRac s limited Warra...

Страница 3: ...t rail sets Apply sealant into the hole and on the shafts of the lag bolts Seal the underside of the L feet with a suitable weatherproof sealant Securely fasten the L feet to the roof with the lag bolts Ensure that the L feet face as shown in Figure 6 or Figure 7 The single slotted square side of the L foot must always lie against the roof with the double slotted side perpendicular to the roof Fig...

Страница 4: ...bove the rafters Adjust as needed following the guidelines in Figure 10 as closely as possible Installing standoffs Drill 3 16 inch pilot holes through the underlayment into the center of the rafters at each standoff location Securely fas ten each standoff to the rafters with the two 5 16 x 31 2 lag bolts provided with it Verify that the lag bolts you use are adequate for your installa tion by fol...

Страница 5: ...tach the rails to the footings with the flange nuts Ensure that the rails are oriented to the footings as shown in Figure 6 7 9 or 10 whichever is appropriate Aligning the Rail Ends Align one pair of rail ends to the edge of the instal lation area Fig 13 or Fig 14 The opposite pair of rail ends will overhang the side of the installation area Do not trim them off until the installation is complete I...

Страница 6: ...odule as needed and securely tighten the flange nuts 15 ft lbs Installing the Other Modules Lay the second module face down glass to glass on the first module Connect intermodule cable to the second module and close the J box cover Turn the second module face up Fig 16 With T bolts mid clamps and flange nuts secure the adjacent sides of the first and second modules Align the second module and securely...

Отзывы: