7
3.4 Momentary Switch (UP/Down Switch)
Position
No.
Functional Select (NS)
Up/Down Switch
0
Normal
N/A
1
Gain Adjustment
Move up or down to adjust gain
2
Reference Adjustment
Move up or down to adjust reference
3
Factory Page
Move up or down to recall factory page
4
User Page 1
Up: Recall; Down: Save
5
User Page 2
Up: Recall; Down: Save
6
User Page 3
Up: Recall; Down: Save
7
User Page 4
Up: Recall; Down: Save
8
Reserved
9
Reserved
A
Reserved
B
Reserved
C
Reserved
D
Reserved
E
Reserved
F
Reserved
Camera settings can be saved into four different user pages. Once the user page is saved and set
between shutter speeds 4 and 7, it will be activated as long as the camera is powered ON. User
Page works in both rear plate control and RS232C communication selections.
3.5 Gain Control (AGC/MGC)
Note: This gain potentiometer only applies to cameras without Up/Down switch
on rear plate.
Manual gain control (MGC)
MGC is standard factory setting on this camera. The manual gain control can be adjusted from 4 dB
to 36 dB. Adjusting the gain potentiometer located on rear panel will change the gain value.
Automatic gain control (AGC):
AGC is not available and it is not recommended to use. Contact UNIQ for further details.
Figure 6. Gain potentiometer
Figure 5. Up/Down Switch