background image

USH

COMPACT HIGH-CAPACITY COMPRESSION TYPE LOADCELL

 

OPERATION MANUAL

01AUG2020REV.1.06

1.Product outline

USH series are compact compression type loadcells with high-capacity. 

There are suitable for built-in applications.

2.Handling prohibitions and precautions

3.Installation procedure

(1) For loadcell mounting, be sure to use proper screws by the specifications. Screw insertion length should

be around 1.5times longer than diameter of a screw. Screws must be tightened at instructed torque. Use

screw locking adhesive if needed.

Recommended tightening torque.....M2: 

0.32 N·m

, M4: 

2.7 N·m

(2) The base plate must be made of steel having enough rigidity. Also its flatness should be 0.01mm or less

and surface roughness should be less than Ra3.2.

(3) The load plate must be made of steel having enough rigidity and hardness. Also its flatness should be

0.01mm or less, surface roughness should be less than Ra3.2, and hardness should be more than HRC50.

The loadcell characteristics may be changed with the flatness of the base.

4.Wiring color of loadcell cables

5.Indicator connection

Check the signal name and wiring color before connection.
(1) The cable of USH loadcell has 6 bare wire ends. Therefore USH should be used with an indicator that

accepts 6-wire input. In case USH is used with a 4-wire input indicator, both +EXC and +S wires must be

inserted  to  +EXC  terminal  of  an  indicator,  also  both  -EXC  and  -S  wires  must  be  inserted  to  -EXC

terminal of an indicator. In this case, sensitivity may change a little.

Please connect SHIELD wire to SHIELD terminal of indicator.

Since load cell main body is insulated from SHIELD cable, make sure main body and indicator ground

point is connected in single-point grounding.

(2) Apply  the  recommended  voltage  for  the  excitation.  If  the  applied  voltage  exceeds  the  maximum

excitation voltage, USH may get permanent damage.

(3) To  extend  loadcell  cable,  make  sure  to  use  a  cable  with  the  same  diameter  or  bigger  diameter  than

standard cable. A voltage drop may occur when small diameter cable (having high resistance) is used,

and it may affect the result of measurement.

Re-calibration with an standard weight could be needed if USH is used with a 4-wire input indicator.

Please consult our sales representative for cable extension.

Prohibitions

Do not disassemble this product.
Avoid dropping or giving a shock to the product.

Precautions

Do not install the product in the following environments:

- In an atmosphere with corrosive or combustible gases;

- Locations where temperature or humidity exceeds 

  specifications;

- Locations subject to drastic temperature fluctuations or 

  icing and condensation;

- Locations exposed to direct sunlight;

- Locations subject to direct vibration or shock

Consult us if this product is to be used under a special

environment.

Provide sufficient strength to the installation location.

Perform adequate isolation if the product is used in the

following locations:

- Locations subject to noise such as static electricity;

- Locations subject to strong electric field and intense 

  magnetic field.

Perform electric welding before mounting the loadcell.

Take caution not to make current flow in the loadcell if

the welding needs to be performed after mounting.

Handle this product as industrial waste when disposing.

Core wire

Signal name / wiring color

+EXC

+S

-S

-EXC

+SIG

-SIG

SHIELD

Six wires

Red

Yellow

Orange

Black

Green

White

Blue

Prohibited actions while operating the product 

(Prohibited actions)

Events that may cause injury to personnel or material damage 

in case of misuse.

Bolt

Load direction

Load plate

Loadcell

Base plate

There is a hollow at the 

bottom of load cell. 

For installation, make sure 

no load is applied on that area.

6.Calibration

If calibration is needed, do it on indicator. For more information, refer to the manual of indicator.

Actual load calibration

In this calibration method, actual load is applied to a loadcell, and the value of the actual load is input using

the keys. Accurate calibration with minimal error can be performed.

Prepare a reference item such as a weight in advance.

Equivalent input calibration

In this calibration method, only the rated output value and the rated capacity value of the loadcell are input

using the keys. This method does not involve actual load.

The values are stated on the attached data sheet upon the purchase of loadcell.

7.Trouble shooting

Determine whether the error is occurring on the loadcell side or the indicator side.

Check the damage of USH in the following  ways.
(1) In case a load is applied larger than safe overload or a load in unexpected direction is applied to the USH,

make sure to check if it didn’t get damaged after recalibration.

(2) When the reading on indicator is unstable or odd, do an inspection as follows after checking wiring and

precautions.

 Check the input resistance of loadcell under no-load condition. (bEXC and -EXC)

 Check the output resistance of loadcell under no-load condition.(bSIG and -SIG)

 Check the signal output of loadcell (Zero-balance) under no-load condition

In case measured values above are out-of-specification, please consult us.
If no problem found on USH, check the indicator in the following ways.
(1) Disconnect the USH from indicator. Check if the reading on indicator is near 0, while short the input

terSIG and -SIG).

(2) Measure the voltage of the output terEXC and -EXC) of indicator, and verify if the excitation

voltage is applied properly.

For more information, refer to the manual of indicator.

Six-wire type loadcell 

 Six-wire type indicator

Six-wire type loadcell 

 Four-wire type indicator

EXC

S

SIG

SIG

SHIELD

S

EXC

EXC

S

SIG

SIG

SHIELD

S

EXC

Loadcell side

Indicator side

Loadcell side

Indicator side

IN

IN

OUT

OUT

EXC

SIG

SIG

SHIELD

EXC

EXC

S

SIG

SIG

SHIELD

S

EXC

IN

IN

OUT

OUT

* SHIELD wire is not connected to load cell main body.

7HVWHU

قٔك

قٕك

ق5HGك

ق:KLWHك

ق%ODFNك
ق*UHHQك

ق%OXHك

ق2UDQJHك

ق<HOORZك

EXC

S

SIG

SIG

SHIELD

S

EXC

IN

IN

OUT

OUT

Disconnect  the  USH  from  the

indicator.  And  verify  if  the  input

resistance of loadcell (bEXC

and -EXC) is within the specification

range under no-load condition.

7HVWHU

قٔك

قٕك

ق5HGك

ق:KLWHك

ق%ODFNك
ق*UHHQك

ق%OXHك

ق2UDQJHك

ق<HOORZك

EXC

S

SIG

SIG

SHIELD

S

EXC

IN

IN

OUT

OUT

Disconnect  the  USH  from  the

indicator.  And  verify  if  the  output

resistance of loadcell (bSIG

and -SIG) is within the specification

range under no-load condition.

7HVWHU

قٔك

قٕك

,QGLFDWRU

ق5HGك

ق:KLWHك

ق%ODFNك
ق*UHHQك

ق%OXHك

ق2UDQJHك

ق<HOORZك

EXC

S

SIG

SIG

SHIELD

S

EXC

EXC

S

SIG

SIG

S

EXC

IN

IN

OUT

OUT

Connect the USH with an indicator. 

And measure the output voltage 

(Vout[mV/V]) under no-load 

condition, while an excitation 

voltage (Vin[V]) is applied. Verify if 

the signal output of loadcell 
(          [mV/V]) is within the 

specification range. (Zero-balance)

Vout

Vin

8.External dimension

9.Specifications

Model

USH-10KN

USH-20KN

USH-50KN

Rated capacity

10

20

50

kN

Rated output

1±20%

mV/V

Safe overload

200

%R.C.

Zero balance

±20

%R.O.

Non-linearity

0.2

%R.O.

Hysteresis

0.15

%R.O.

Repeatability

0.1

%R.O.

Compensated temperature range

-10 to +70

Safe temperature range

-30 to +85

Temperature effect on zero

0.2

%R.O./10

Temperature effect on span

0.2

%R.O./10

Input resistance

Approx. 1000

Ω

Output resistance

Approx. 1000

Ω

Recommended excitation voltage

5

V

Maximum excitation voltage

7.5

V

Insulation resistance (DC50V)

1000 or more

Cable

φ

2.5 6-conductor flexible cable (3m)

Cable end: 7 wires

Deflection at rated capacity

0.06

0.07

mm

Natural frequency

20

15

kHz

Loadcell material

Stainless steel

Weight

0.1

0.18

kg

USH-10KN, USH-20KN

USH-50KN

8QLWPP

Load direction

25

22

ȭ

40

6.1

ȭ

13

SR60

P.C.D.32

120°

3-M4 Depth 6

ȭ

2.5 6-conductor

flexible cable (3m)
Cable end: 7 wires

Load direction

ȭ

26

13

12

SR40

ȭ

8

4.1

P.C.D.22.75

120°

3-M2 Depth 3

ȭ

2.5 6-conductor

flexible cable (3m)
Cable end: 7 wires