12
3
Setting Procedures
12
Setting Procedures
Chapter
3
3-2.
List of setting values
■
Torque
Setting items having * mark are displayed when the UTM capacity is set to OTHER.
■
Rotation speed
Name
Default
value
Range
Setting
protection
Calibration
protection
0
Zero calibration (ZERO CAL.)
0
-5.000 to 5.000 [V]
◎
1
UTM capacity (UTM CAP.)
18: 1000
Nm
0: 0.03, 1: 0.05, 2: 0.1, 3: 0.2, 4: 0.3,
5: 0.5, 6: 1, 7: 2, 8: 3, 9: 5, 10: 10,
11: 20, 12: 30, 13: 50, 14: 100,
15: 200, 16: 300, 17: 500, 18: 1000,
19: 2000, 20: 3000, 21: 5000,
22: 10000 [Nm], 23: OTHER
◎
2
Sign (SIGN)
0: NORMAL
0: NORMAL, 1: REVERSE
2: ABSOLUTE
◎
3
Minimum scale (MIN. SCALE)
0: 1
0: 1, 1: 2, 2: 5, 3: 10, 4: 20,
5: 50, 6: 100
◎
4
Low-pass filter (LPF)
3: 300 Hz
0: 10, 1: 30, 2: 100, 3: 300,
4: 1k, 5: 3k, 6: 10k, 7: 30k [Hz]
◎
5
Moving average (AVERAGE)
0
0 to 999
◎
6
Upper limit (UPPER LIM.)
9999
-9999 to 9999
◎
7
Lower limit (LOWER LIM.)
-9999
-9999 to 9999
◎
8
Other capacity (OTHER CAP.) *
100
1 to 99999
◎
9
Unit (UNIT) *
1: Nm
0: mNm, 1: Nm, 2: kNm
◎
10
Decimal point (DECIMAL P.) *
0: 0000
0: 0000, 1: 000.0, 2: 00.00, 3: 0.000
◎
Name
Default
value
Range
Setting
protection
Calibration
protection
0
Unit (UNIT)
0: rpm
0: rpm, 1: min
-1
◎
1
Minimum scale (MIN. SCALE)
0: 1
0: 1, 1: 2, 2: 5, 3: 10, 4: 20,
5: 50, 6: 100
◎
2
UTM type (UTM TYPE)
1: UTM
Ⅱ
0: UTM, 1: UTM
Ⅱ
◎
3
Moving average (AVERAGE)
0
0 to 999
◎
4
Quick stop mode (QUICK STOP)
1: ON
0: OFF, 1: ON
◎
Содержание TM400
Страница 1: ...01FEB2018REV 1 06 TM400 PORTABLE TORQUE MONITOR OPERATION MANUAL ...