19
4
FOR GREATER USE OF THE PRINTER
19
FOR GREATER USE OF THE PRINTER
Chapter
4
4-2.
Details of Each Setting
The details and operating method of each setting are explained below. For how to enter the setting
mode and its operating method, see the "4-1.Basics of Settings" on page 15 described in the
previous chapter.
Change the date and time.
The date and time of the M252B are factory-set.
Correct it when it is necessary.
Example of setting - Setting 8:30 p.m., June 6, 2000 -
Select the type of data to be printed for each ch.
Four types of data can be selected.
Name of setting
01: Date/Time
Initial value
The current time has been set at the time of delivery.
Input format
YYYYMMDDhhmm [ENT]
Year
Date
Time
(Fixed)
Caution
- Input all four digits for the year.
- Input "0" at the start of a one-digit month/date.
- Input the time on a 24-hour basis, and input "0" at the start of one-digit
hours/minutes.
- A battery is necessary for operation of the clock. The life of the battery
is approx. 8 years.
Name of setting
02: Print Data Selection Ach
03: Print Data Selection Bch
Selection item
0. Gross (initial value)
1. Net
2. Tare
3. Indicated
Reference
- When printing values indicated by load cell indicators, normally set the
M252B at [3. Indicated]. Select Gross, Net or Tare only when you want to
specifically print these.
- When printing values indicated by digital indicators, normally set the M252B
at [3. Indicated].
Caution
The type of print data selected here is valid only when data is printed through
the SI/F. When data is printed through the BCD input or RS-232C interface,
input data is printed irrespective of the type selected here.
01: Date/Time
Year
→
→
Date
Time
Fixing
operating
02,03: Print Data Selection Ach/Bch
Содержание M525B