8
2
PRINTER PREPARATIONS
8
PRINTE
R PRE
P
ARATIONS
Chapter
2
2.
Open the flip panel downward. Catch the upper left of the installed ribbon cassette
with your finger (with your fingernail), and pull and remove it frontward.
3.
Install a new ribbon cassette, being careful about its orientation.
Turn the ribbon cassette upside down (in the direction that reverses the PULL
marking as shown below), and push it in until you hear it click. Then close the flip
panel, and push in the push panel firmly until you hear it click.
2-2.
Power Input Connection
For connection to terminal blocks, use cables with crimp contacts (M3) as shown in the illustration
without unbraiding their ends.
Connect the AC power cord. The input voltage is 100V - 240V AC. The frequency is 50/60Hz.
1.
Check that no power is applied.
2.
Remove the terminal block cover.
3.
Remove the screws (three) from the
terminal block. Fit the crimp contacts
(M3) to the screw holes, and fix them
with the screws.
4.
Install the terminal block cover, and fix it
with the screws.
* A parallel two-core power cable with crimp contacts is attached to the product.
AC IN
F.G.
Within 6mm
L N
F.G.
(Functional ground)