7.FUNCTION AS A WEIGHT CHECKER
48
Conditional formula
Near zero
Turns ON when weight value
≦
NEAR ZERO set value.
Taking in
Turns ON when data is being taken in.
Over
Turns ON when RESULT > FINAL S OVER SETTING.
Go
Turns ON when FINAL SETTING - UNDER SETTING
≦
RESULT
≦
FINAL S OVER SETTING.
Under
Turns ON when RESULT < FINAL SETTING - UNDER SETTING.
Complete
Turns ON for the COMPLETE signal output time after completion of taking-in of data
and after processing of RESULT calculation.
* The RESULT calculation processing time is approximately 50msec.
* The OVER/FINAL/UNDER signal turns ON only while the COMPLETE signal is output.
Select NEAR ZERO COMPARISON from GROSS/NET by the setting of NEAR ZERO COMPARISON.
Select OVER/UNDER COMPARISON from GROSS/NET by the setting of OVER/UNDER COMPARISON.
7-1-2. Static mode
0
NET
Time
Near zero
Take-in interval
Empty count
When the SAMPLE MODE is
Final
Over
Under
Measurement
Measurement
Measurement
Near zero
Taking in
Over
OFF
t1
ON
Go
Under
Complete
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
t1: Complete output time
set at 100%.
start mode
start
reset