7.FUNCTION AS A WEIGHT CHECKER
47
7. FUNCTION AS A WEIGHT CHECKER
7-1. About Measurement
Measurement can be carried out in
“DYNAMIC
MODE”
and
“STATIC
MODE”
.
Select by the external input/output signal
“
MEASUREMENT START MODE
”
(pin 31).
7-1-1. Dynamic mode
Near zero
NET
Time
Measurement
Measurement
Measurement
Near zero
Taking in
Over
ON
t1
ON
Take-in interval
The average of this part corresponds to the RESULT.
(Here, the SAMPLE MODE is set at 50%.)
Final
Over
Under
Go
Under
Complete
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
t1: Complete output time
start mode
start
reset