7.CONTROL SIGNAL (External I/O Connector)
97
7-4. External Input Signal
7-4-1. Running (edge input)
Feed is accumulated while the external signal is ON.
However, it does not operate during ERROR MEASURE and SPEED INPUT COUNT
MEASURE
7-4-2. Display 1 change (level input)
Depending on the state of input signal, the data types to be displayed in the upper pane
of the comparison screen are selected as indicated in the table below: [DISP DATA
SELECT1] must be switched to “EXTERNAL INPUT”.
7-4-3. Display 2 change (level input)
Depending on the state of input signal, the data types to be displayed in the lower pane
of the comparison screen are selected as indicated in the table below: [DISP DATA
SELECT2] must be switched to “EXTERNAL INPUT”.
RUNNING signal is turned on while accumulation is being performed.
OFF
ON
Running
Indefinite (max. 50 msec)
DISP. CHANGE
4
2
1
BELT SPEED
OFF
OFF
OFF
WEIGHT DENSITY
OFF
OFF
ON
FEED RATE
OFF
ON
OFF
LOAD RATIO
OFF
ON
ON
FEED RATIO
ON
OFF
OFF
GROSS WEIGHT
ON
OFF
ON
CONTROL RATE
ON
ON
OFF
CONTROL DEVIATION
ON
ON
ON
DISP. CHANGE
4
2
1
BELT SPEED
OFF
OFF
OFF
WEIGHT DENSITY
OFF
OFF
ON
FEED RATE
OFF
ON
OFF
LOAD RATIO
OFF
ON
ON
FEED RATIO
ON
OFF
OFF
GROSS WEIGHT
ON
OFF
ON
CONTROL RATE
ON
ON
OFF
CONTROL DEVIATION
ON
ON
ON