6.DISCHARGING CONTROL MODE
91
6-7. Upper/Lower Limit Comparison /
Upper/Lower Limit Comparison Mode /
Near Zero Comparison / Final and Comparison /
Over/Under Comparison Mode
It enables to select the weight (Gross/Net) to be compared and the timing of comparison at the each
comparison point of Upper/Lower limit, Near Zero or Over/Under.
a)Upper/Lower limit
(Select from Gross weight / Net weight /
comparison
Comparison OFF)
b)Upper/Lower limit
(Select from Comparison Regularly /
comparison mode
External Judging ON)
c)Near Zero comparison
(Select from Gross weight / Net weight /
Comparison OFF / | Gross weight | / | Net weight |)
d)Over/Under comparison
(Select from Gross weight / Net weight /
Comparison OFF)
e)Over/Under comparison mode
(Select from Comparison Regularly /
External Judging ON / Complete Signal ON /
Complete ON Hold)
Operation
a), c), d)
1) Select setting mode 2.
2) Set Upper/Lower limit comparison, Near Zero comparison and Final and Over/Under compari-
son. (1-Weighing Function 1)
→
→
→
F
CNG/ENT
CNG/ENT
2
LOWER
Final and Over/Under comparison
2 : Comparison OFF
1 : Net weight
0 : Gross weight
Upperr/Lower limit comparison
2 : Comparison OFF
1 : Net weight
0 : Gross weight
Near Zero comparison
4 : ON when
|Net weight|
≦
Near Zero
setting value
3 : ON when
|Gross weight|
≦
Near Zero
setting value
2 : Comparison OFF
1 : ON when
Net weight
≦
Near Zero
setting value
0 : ON when
Gross weight
≦
Near Zero
setting value
→
→
→
ZERO
1
UPPER
CNG/ENT
CNG/ENT
Содержание F701-C