72
9
System Settings and Operations
72
Syste
m
Settin
gs and
Ope
ratio
ns
Chapter
9
9-8.
RS-232C check
Checking of receiving data of RS-232C and compulsory
transmitting of data are implemented.
When implementing the check, set the mode of RS-232C
communication type to 0: Command in advance.
* Valid only when a mode of RS-232C communication type is
0: Command
* The number of received characters and the number of received CR are cleared once the power
supply is turned OFF. They are also cleared when a mode of RS-232C communication type and I/
F setting of RS-232C are changed.
When the
key is pressed, the same message is output as a linked value reading command.
* In RS-232C check display, the panel does not return to indicated value display even without key
operation.
9-9.
RS-485 check
Checking of receiving data of RS-485 and compulsory
transmitting of data are implemented.
When implementing the check, set the mode of RS-485
communication type to 0: Command in advance.
* Valid only when a mode of RS-485 communication type is
0: Command
* The number of received characters and the number of received CR are cleared once the power
supply is turned OFF. They are also cleared when a mode of RS-485 communication type and I/F
setting of RS-485 are changed.
When the
key is pressed, the same message is output as a linked value reading command.
* In RS-485 check display, the panel does not return to the indicated value display even key
operation.
Number of
Number of
received CR received characters
HOLD
R A
+
1 0 0
0 0
.
Indicated value
Terminator
Number of
received CR
Number of
received characters
HOLD
R A
+
1 0 0
0 0
.
I D
ID No.
Terminator
Indicated value
Содержание F325
Страница 1: ...01JUN2015REV 1 01 DIGITAL INDICATOR F325 OPERATION MANUAL...
Страница 153: ...142 15 Specifications 142 Specifications Chapter 15 When BCO BSC option is selected Unit mm When BSC option is selected...
Страница 154: ...143 15 Specifications 143 Specifications Chapter 15 When DAV DAI option is selected Unit mm When DAI option is selected...
Страница 155: ...144 15 Specifications 144 Specifications Chapter 15 When RS 232C option is selected Unit mm...
Страница 160: ......