39
5
FUNCTIONS
39
FUNCTIONS
Chapter
5
5-14.
Sequence Control
■
Normal Sequence (With Judgment)
●
The complete signal output timing depends on the setting of the complete output mode of setting
code 26.
●
Over/Under comparisons are made, holding the weight value, when the complete output is ON,
deregarding the setting of Over/Uunder comparison mode of setting code 27.
●
Upper/Lower limit comparisons are always made deregarding the setting of the Upper/Lower
limit comparison mode of setting code 28.
t1: Comparison inhibit time; comparison inhibit time of setting code 10
t2: Judging time; judging time of setting code 11
t3: Complete output time; complete output time of setting code 12
0
Final - Set Point 1
Final - Set Point 2
Final - Compensation
Final
Weight
Over
Under
Time
Start
Stop
SP1
SP2
SP3
Complete
Judgment (Over or Go or Under)
Judging time
ON
OFF
Complete output time
t3
ON
ON
ON
ON
t2
t1
t1
Hold
Comparison inhibit time
Near zero
ON