36
5
FUNCTIONS
36
FUNCTIONS
Chapter
5
■
Upper/Lower Limit Comparison Mode (Setting Code 28)
Setting/
0: Continuous comparison
1: Comparison when the external judgment input is ON
■
Comparison Inhibit Time/ Judging Time/ Complete Output Time
(Setting Code 10 to 12)
Comparison inhibit time/ Judging time
These functions inhibit comparison for a fixed period so that control and judgment will not be
operated inappropriately due to mechanical vibrations caused by opening and closing of valves.
Complete output time
Set the length of the complete signal (complete relay) to be output when weighing is completed.
Setting range and code No. of each set value
Set value
Setting range
Initial value
Code No.
Comparison
inhibit time
000 to 999
(0.00 to 9.99 sec.)
50
10
Judging time
150
11
Complete
output time
300
12
0
Final - Set Point 1
Final - Set Point 2
Final - Compensation
Comparison inhibit time
Judging time
Weight
Final - Set Point 1
Final - Set Point 2
Final - Compensation
Final
Weight
Near zero
0
Time
Stable
Complete
Complete
ON
ON
Complete output time
Over
Under
output time