UP-2210 Hardware installation and configuration manual 

English version 1.1

 

 

Содержание UP2210

Страница 1: ...UP2210 UP 2210 Hardware installation and configuration manual English version 1 1...

Страница 2: ...er quality monitoring system PQ Secure system consists of three main components the meter communication equipment and a specially designed analysis and evaluation program PQ Secure The PQ Secure syste...

Страница 3: ...s and 3 PT s Line to line voltages 23 4 4 7 3 phase measurement with direct voltage 2 CT s Line to neutral 24 4 4 8 3 phase measurement with direct voltage 3 CT s and neutral Line to neutral voltages...

Страница 4: ...Settings in the modem 59 6 6 LINE DIVIDER 59 6 6 1 Configuring the PentiLine PRO 60 7 GPS CLOCK SYNCHRONISATION MODULE 61 7 1 INSTALLATION 62 7 1 1 Connecting the GPS to the Display port 62 7 1 2 Conn...

Страница 5: ...tallation site has no uninsulated wires and standing water near the measuring instrument The instrument case must never be dismantled under any circumstances Make sure that no loose or hanging items e...

Страница 6: ...agreement with the other party Unipower AB does not accept liability in respect of customers failure to observe clauses and copyrights of Unipower and its suppliers and third party products of system...

Страница 7: ...ented and approved by the manufacturer Apart from the warranty obligations above Unipower AB is not bound by other warranties or obligations unless these have been agreed between the parties or are im...

Страница 8: ...sists of three parts the measure device communication equipment and a computer for storing the measured data A PQ Secure system can have the following configuration PQ Secure is a highly advanced and...

Страница 9: ...ay be equipped with RS 232 RS 485 built in modems and Ethernet ports This means that communication is possible using a range of media such as a standard telephone lines signal cables GSM phones local...

Страница 10: ...of the system Used to present measure data from the SQL database and to configure the system PQ Online Used to present real time values from the meters and to configure the meters PQ Schedule Manages...

Страница 11: ...database is approximate 0 35 to 0 9 GB per Meter per Month MM depending on configuration With standard configuration 0 54 GB MM is a good average This includes all data both statistical and events Wh...

Страница 12: ...and durable However you should still think carefully about the environment which should be clean and dry and have a normal ambient temperature The communication with the unit can also influence where...

Страница 13: ...r to the drawing below When mounting the meter leave enough room at the side to prevent the contacts from getting jammed It is important to install the meter as close as possible to the measured objec...

Страница 14: ...0 Hardware installation and configuration manual 14 Note Make sure there is sufficient room to link all connectors A minimum 20 30 mm is required The display module connector needs 80mm clearance Figu...

Страница 15: ...utputs under certain conditions for example when a transient of a certain level is recorded The digital outputs are configured using the PQ Online program Digital inputs Optional The digital inputs ar...

Страница 16: ...rnal UPS type battery source in order to prevent power failure disturbances The cable connected to the power supply unit of the UP 2210 unit must be 0 25 2 5 mm2 23 12 AWG and fitted with a 2A fuse Lo...

Страница 17: ...nect the polarities correctly because incorrect polarity on the voltages channels will shift the voltage signal through 180 affecting the power calculations Connect the voltage channels in accordance...

Страница 18: ...ith direct voltage and one CT Line to neutral voltage Figure 10 The above wiring diagram is used for single phase measurement in low voltage networks The voltage channel of the unit is connected direc...

Страница 19: ...of the unit is connected to PT for measuring line to neutral voltage The current channel is connected to existing instrument transformer allowing the measurement of high currents e g directly from the...

Страница 20: ...ed channels Always protect the voltage inputs with a suitable fuse in each conductor on the secondary side of the PT The connection for this type of measurement is as follows Channel Measured object C...

Страница 21: ...nnected to CT s normally 1 5 A AC secondary Two voltage channels are measured and the third is calculated in the measuring instrument Always protect the voltage inputs with a suitable fuse in each con...

Страница 22: ...d current channels are connected to the CT s normally 1 5 A AC secondary Always protect the voltage inputs with a suitable fuse in each conductor on the secondary side of the PT Two current channels a...

Страница 23: ...ormally 63 V AC secondary to earth for supplying line to line voltages and current channels are connected to CT s normally 1 5 A AC secondary Always protect the voltage inputs with a suitable fuse in...

Страница 24: ...suring line to neutral voltage 230 V and therefore do not require an instrument transformer PT The current channels are connected to existing instrument transformers allowing the measurement of high c...

Страница 25: ...asuring line to neutral voltage 230 V and therefore do not require an instrument transformer PT The current channels are connected to existing instrument transformers allowing the measurement of high...

Страница 26: ...f the unit are connected to PT s normally 63 V AC secondary to earth for supplying line to line voltages and current channels are connected to CT s normally 1 5 A AC secondary Always protect the volta...

Страница 27: ...unit are connected to PT s normally 63 V AC secondary to earth for supplying line to line voltages and current channels are connected to CT s normally 1 5 A AC secondary Always protect the voltage in...

Страница 28: ...ls of the unit are connected to PT s normally 63 V AC secondary to earth for supplying line to line voltages and current channels are connected to CT s normally 1 5 A AC secondary Always protect the v...

Страница 29: ...the unit are connected to PT s normally 63 V AC secondary for supplying line to earth voltages and current channels are connected to CT s normally 1 5 A AC secondary Always protect the voltage inputs...

Страница 30: ...easuring line to neutral voltage 230 V and therefore do not require an instrument transformer PT The current channels are connected to existing instrument transformers allowing the measurement of high...

Страница 31: ...ine to neutral voltage 230 V and therefore do not require an instrument transformer PT The current channels are connected to existing instrument transformers allowing the measurement of high currents...

Страница 32: ...WER UP 2210 Hardware installation and configuration manual 32 4 4 15 SP 2CT 2PT Figure 24 The above wiring diagram is used for Channel Measured object Channel Measured object U1 L1 I1 CT Ref Neutral I...

Страница 33: ...OWER UP 2210 Hardware installation and configuration manual 33 4 4 16 SP 2CT DV Figure 25 The above wiring diagram is used for Channel Measured object Channel Measured object U1 L1 I1 CT Ref Neutral I...

Страница 34: ...pedance grounded MV networks the voltage in the transformer s ground point is of interest to study Earth faults and emerging earth faults can be detected by analyzing the ground point voltage If there...

Страница 35: ...rectly and turned the ammeters in the right direction If a correct connection is done the voltage phases should be separated with 120 degrees with the first phase the read phase pointing to the right...

Страница 36: ...used to track them Connect your UP 2210 to measure line to line voltages U1 U3 and phase currents I1 I3 according to one of the sections 4 4 3 4 4 4 4 4 5 and 4 4 6 depending on how many PT CT there...

Страница 37: ...ower Quality point of view line to line voltages should always be measured see sections 4 6 1 4 6 2 and 4 6 3 This is in accordance with existing Power Quality standards like EN 50160 As an alternativ...

Страница 38: ...changes from a zero value to the upper limit If you have signals with normally high values active you can via the configuration in PQ Online invert the signal to trigger events when the signal drops...

Страница 39: ...ght 92 mm 0 0 8mm Depth needed is 99 mm plus space for 25 pin DSUB connector at back Troubleshooting In case the display would freeze or misbehave due to any kind of outer disturbance this can easily...

Страница 40: ...tion this option shall of course be activated in the instrument and configured for this kind of communication with PQ Online The meter must be given a unique IP address Consult with your network admin...

Страница 41: ...onfiguration manual 41 For successful communication use right kind of cable for each equipment It is important to lock the modem to the bit rate used by the meter Figure 32 shows how the UP 2210 is co...

Страница 42: ...t rate to automatic mode adjusts to the other equipment AT B1 Sets the bit rate to a fixed speed same as the speed set in HyperTerminal ATS0 1 Sets the modem to automatically answer after 1 ring the n...

Страница 43: ...igure the modem Start HyperTerminal for example as follows Start Programs Accessories Communication HyperTerminal A window opens where you start by entering a name for your connection and then click o...

Страница 44: ...t click on OK to open HyperTerminal where you can configure the modem using the commands described above When you have finished configuring the modem exit by typing ATE0 Enter to disable the text func...

Страница 45: ...phone so that it can find its GSM network and register Remember to remove the PIN code or the SIM card will not work with a GSM modem The communication speed for the GSM modem is usually 9600 or 19200...

Страница 46: ...P 2210 Hardware installation and configuration manual 46 Figure 37 shows how an UP 2210 is connected to a GSM modem Figure 37 Article Description 22 9030 GSM modem 22 9080 Communications cable 9 pin 9...

Страница 47: ...UP 2210 Ext modem Unilyzer 902 use special modem cable and the modem s power supply Check the LEDs on the modem when the power is connected The yellow LED should light up immediately with a firm ligh...

Страница 48: ...no PIN code and it must have a public static IP address The router must be set up to forward UDP traffic on port 16421 to the meter s local IP address on the inside LAN of the router If multiple meter...

Страница 49: ...UNIPOWER UP 2210 Hardware installation and configuration manual 49 Figure 39 shows two UP 2210s connected to a 3G router Figure 39 GPRS or 3G router Standard switch...

Страница 50: ...e multi drop This is useful in large sub stations where you want to connect several meters to the same modem RS 485 communication can be direct from the computer using a signal converter to the meter...

Страница 51: ...ers in substations The environment is normally quite different from an office both regarding physical environment like temperature and EMC environment The figure below shows a meter connected to the m...

Страница 52: ...UNIPOWER UP 2210 Hardware installation and configuration manual 52 Start with setting all DIP switches in factory default mode Then change according to the following pictures...

Страница 53: ...UNIPOWER UP 2210 Hardware installation and configuration manual 53...

Страница 54: ...UNIPOWER UP 2210 Hardware installation and configuration manual 54 Finish by restarting the modem...

Страница 55: ...e communications settings in UP 2210 Use PQ Online to do this Figure 42 6 5 1 2 Settings in the modem Meters that use RS 485 don t send commands to the modem to answer incoming calls this is to avoid...

Страница 56: ...ays choose an industry class modem rather than office equipment when building communications solutions for your meters in substations The environment is normally quite different from an office both re...

Страница 57: ...UNIPOWER UP 2210 Hardware installation and configuration manual 57...

Страница 58: ...UNIPOWER UP 2210 Hardware installation and configuration manual 58 If you want to use the modem with RS 232 communication change S1 4 from on to off Power the modem off on to make changes active...

Страница 59: ...oming calls this is to avoid communication collisions Because of this the modem must be configured to answer automatically command ATS0 1 See section 6 2 2 on how to do this 6 6 Line divider A line di...

Страница 60: ...after each command and if there has been an error you will just hear one long signal When you have finished replace the handset and the line divider configuration is complete For more commands refer t...

Страница 61: ...global positioning system GPS satellites With accurate real time clock synchronization the comparison between events such as sags swells or transients between different sites in the electrical networ...

Страница 62: ...installation Connect the GPS to the Adapter and the adapter to the UP2210 through a straight UTP Patch cable Check the adapter labels carefully The GPS and the UP2210 must be connected to the specifi...

Страница 63: ...gure 49 GPS configuration This is all that Is needed to configure the UP2210 to use GPS synchronization If everything is connected correctly and the GPS finds enough satellites the Sync led on the UP2...

Страница 64: ...meter there are several protective mechanisms in the software that prevent incorrect time from setting the meter Each time for instance is verified twice before setting When the clock is set in the m...

Страница 65: ...tion in the order described below 8 1 Installation procedure Depending on the architecture of the PQ Secure the different programs should be installed on different computers Please see PQ Secure SQL U...

Страница 66: ...pt the recommended settings Check that the installation path is correct We recommend C Program Files Unipower PQ Online If the installation doesn t start automatically click on the Windows Start butto...

Страница 67: ...the PC After a few seconds you should see a message that the meter is being connected and then a menu like in Figure 53 Connecting the USB cable You can choose to start PQ Online for configuration or...

Страница 68: ...sis 8 4 1 Connect When you have started the program and pressed Connect a connect to meter dialogue will automatically appear Here you select the communication method chosen for connecting the compute...

Страница 69: ...onfiguration manual 69 Select the appropriate alternative and click the Connect button The status window enables you to follow the communication process SmartCom Server Here you specify the meters Ser...

Страница 70: ...he actual settings see Figure 57 8 4 2 1 Wire connection configuration Settings wizard You can use the settings wizard that guide you through the configuration of your meter Press Setting wizard butto...

Страница 71: ...as Figure 59 show Select the actual configuration Example below shows how to choose a four wire 3 phase configuration with 3 CT s and 3 PT s Select four wire wye as instrument transformer configurati...

Страница 72: ...as in the picture above Tip You can use if you for example want to start over again Press next and select your reference and trig levels see Figure 62 below and then press next and you will get a summ...

Страница 73: ...al 73 Press Next and enter Measure setting name and signature and press Finish to save the settings to the meter see Figure 64 below If you want to save the settings to a file choose Save to file Figu...

Страница 74: ...ge is 11 kV and the secondary 110 V The meter calculates the ratio to 100 The current transformer ratio is 400 5 and is entered as in the picture above Press Next Tip You can use if you for example wa...

Страница 75: ...ave the settings to the meter see Figure 68 below If you want to save the settings to a file choose Save to file C Get settings from file Select your file and opened it You will now see your configura...

Страница 76: ...als D Disturbance E Slowscan settings These are described below A General settings General settings are measurement settings for the meter If you want to edit a value highlight the row by clicking on...

Страница 77: ...are installation and configuration manual 77 B Measure site properties In measure site settings you have several settings You can also here highlight a row and get information about the setting and ed...

Страница 78: ...iguration manual 78 C Storage intervals In storage interval you set the intervals how often actual measurement unit will be stored D Disturbance In disturbances you set values for disturbances such as...

Страница 79: ...If waveform is not enabled you will lose the ability to see disturbances in line line line neutral voltage If waveform is enabled the meter stores the high speed actual sample points The number of sa...

Страница 80: ...ibility to trig on earth faults Normally the voltage sum U1 U2 U3 0 If this is not the case you probably have an earth fault and this trigger starts a recording Current triggers a I1 I3 high trigger W...

Страница 81: ...tions Unipower recommends a configuration of 10 seconds pre trig 120 seconds post trig Note that appropriate settings might take some trial and error before you find optimal storage length for your sy...

Страница 82: ...UNIPOWER UP 2210 Hardware installation and configuration manual 82...

Страница 83: ...t You can also click the start button E to show the variation of the selected C power quality parameters over time The purpose of the trend monitor is to give a quick overview of the power quality wit...

Страница 84: ...e tab B following window appears You can choose which parameters to be shown by selecting them G If you for example want to set a specific colour of U1 then click on the arrow H You will get a dropdow...

Страница 85: ...cation settings In communication settings there are several settings tabs depending on communication type A Settings for Ethernet B Settings for Serial ports C Settings for Wi Fi D Settings for SmartC...

Страница 86: ...In Download data window you can select the file to be downloaded Pressing Custom Interval tab A gives you opportunities to specify an interval from the file that you will download data In the Options...

Страница 87: ...set the time in meter to same time as in System by clicking on arrow E You can restart the meter by pressing on restart meter button F B Manual trig tab Her you can manually trig a sag transient or a...

Страница 88: ...uage A Choose the language you want from the dropdown list 8 4 8 USB port The meter UP 2210 is equipped with a USB port This port doesn t need any settings We recommend you install and use the UniLaun...

Страница 89: ...16 Ground point measurements 34 Ground point voltage 34 GSM modem 45 GSM Modem 13 GSM GPRS modem 56 H HyperTerminal 43 HyperTerminal commands 42 I Impedance grounded 34 36 Inputs 15 Installation 5 12...

Страница 90: ...56 RTC Sync 63 S Server dimensioning 11 Single phase 18 19 24 25 30 31 Software 66 SQL Server 10 System overview 8 T Termination 50 Three phase 20 U UDP port 48 UDP port 40 Undertaking 6 Unilyzer 901...

Отзывы: