Table 5-2: Protection functions and LED flash times.
Times
Protection
Conditions
1
Over Current Error
The current through power devices if inverter
exceeds the limit value of 4.8 A.
2
Over Speed Error
Motor speed exceeds 3000 rpm.
3
Position Tracking Error
Position error value is higher than 180°in motor
run state.
4
Over Load Error
The motor is continuously operated more than 5
seconds under a load exceeding the max.
Torque.
5
Over Temperature Error
Inside temperature of drive exceeds 85 °C.
6
Over Regenerative Voltage
Error
Back-EMF is higher than limit value.
7
Motor Connect Error
The power is ON without connection of the
motor cable to drive.
8
Encoder Connect Error
Cable connection error in Encoder connection of
drive.
10
In-Position Error
After operation is finished, position error more
than 1 pulse is continued for more than 3
seconds.
11
System Error
Error occurs in drive system.
12
ROM Error
Error occurs in parameter storage device (ROM).
15
Position Overflow Error
Position error
value is higher than 180° in motor
stop state.
5.2
Pulse Input Setting Switch (SW1.1)
Indication
Switch Name
Functions
2P/1P
Selecting Pulse
Input Mode
Selectable 1-Pulse input mode or 2-Pulse
input mode as Pulse input signal ON: 1-
Pulse mode OFF: 2-Pulse mode (Default:
2-Pulse mode)
Figure 5-2: Pulse input setting switch.