Chapter 6 Troubleshooting and Component Replacement
66
6.1.6 Failure in Lighting up Part of the Modules in the Cabinet
Causes:
1) Output of the power supply for the modules is faulty.
2) Output of signal which controls the related modules is faulty.
Troubleshooting method:
1) Check DC voltage for the modules.
2) Check the hub card ports or flat cables that control the modules.
6.2 Replacement of Main Components
Before performing maintenance on the LED display, switch off the power to ensure your
personal safety and equipment safety. When installing a new module, connect the flat
cables first and then the power cable and make sure the directions of the modules,
power cable, and flat cables are correct. Keep the accessories (such as screws that are
removed during maintenance) properly in order to re-install them after the component
has been replaced.
6.2.1 Maintenance of Front-Maintenance Cabinets
Uslim
-
O P3.9
、
4.8&P5.9 Replace a module based on the following steps:
Step
Picture
Description
1
Remove the module by
rotating
counterclockwise with
an inner hexagon
handle.