background image

8.

 

Registering and Using RFID keys 

 

 

LL92PR and LL92PRN are adopted industry first key-in mechanism for 
waking up the lock from power saving mode (sleep mode). The key is 
secured in the lock and cannot be take out when the door is open. Key is 
can be taken out after close the door

 

 

A.

 

Register an Owner key 

-

 

First used RF card became an Owner key.   

 

Install LL94AR into the locker.   

 

Insert 3 AA alkaline batteries.

 

 

 

First inserted key become an Owner key. Insert GK91PR RF key for 
registering it as an Owner key. Beeps 3 times and blinking green LED if 
the Owner key registration is done.   

-

 

1 Owner key can be registered for a LL92PR. Owner key registers or 
delete Master keys and Cleaner keys. But cannot operate the lock. 

 

B.

 

Register Master key(s) 

 

Insert Owner key (No need to use Owner key at the first time) and take 

out. LED blinks during registration mode for 8 seconds 

 

Insert another GK91PR to register it as a Master key . Beep 3 times and 
green LED blinks if the registration is done. 

 

Insert another GK91PR for up to 20 in sequence or insert same key twice 
to end the registration.   

 

Example: Insert A key (4 seconds) – insert B key – insert C key – 
insert C key again   

 

Result: Three (A, B and C) Master keys has been registered. 

-

 

Master key can open the lock. But cannot lock. 

 

C.

 

Register & using User key(s) 

 

Insert any Master GK91PR key   

 

Insert an extra GK91PR key (LED blinks during registration mode for 8 
seconds). Beep 3 times and green LED blinks if the registration is done. 

 

Touch another GK91PR key for up to 20 in sequence or insert same key 

twice to end the registration.   

 

Example: Insert any Master key – insert A key – insert B key – insert 
C key – insert C key again 

 

Result: three (A, B and C) User keys has been registered. 

-

 

The User key can lock or unlock LL92PR.   

 

D.

 

Change or delete User key (while lost user key) 

i.

 

Insert any Master key for deleting all registered User keys. 

ii.

 

Register new User keys.   

 
 
 
 
 

Содержание Loxury IX

Страница 1: ...Model No LL92PR LL92PRN 2016 03...

Страница 2: ...y force O Warning alarms for low battery or abnormal status External 9V battery connector for low battery Melody on off setting In use LED icon Auto locking or manual locking 1 year battery life with...

Страница 3: ...r for changing the options Functions Options No of Beep Factory Setting Use of Key Shared Use 1 Assigned Use 2 Default Locking type Auto Locking Manual Locking Default Beep Levels High Default Mid Low...

Страница 4: ...ation mode for 8 seconds Insert another GK91PR to register it as a Master key Beep 3 times and green LED blinks if the registration is done Insert another GK91PR for up to 20 in sequence or insert sam...

Страница 5: ...9 Installation Drawings For Right Hinge Covered Door...

Страница 6: ...For Left Hinge Embedded Door...

Страница 7: ...ry contactors Use any registered Master card to open 11 Reset Memory Clear Memory Possible to delete all registered RF keys and return all of the lock functions back to factory default setting 1 Coupl...

Страница 8: ...out damage if the lock does not work at all Try to open with 9V external battery before doing this emergency opening process 1 Unscrew the side bottom set screw with set screw wrench 2 Rotate the fron...

Страница 9: ...3 Press down inside open pin with driver 4 Insert the emergency opening pin into the emergency opening hole...

Страница 10: ...5 Press the emergency opening pin to the right end and open the door The lock does not work at all after this emergency opening Return the lock to the authorized dealer for rework END...

Страница 11: ...allation if this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the int...

Отзывы: