8
* NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box
immediately starts up, automatically.
BURNER TYPE
NG400
M-.xx...x.25
NG400
M-.xx...x.32
NG400
M-.xx...x.40
NG400
M-.xx...x.50
Output
min.- max. kW
115 - 420
Fuel
Natural gas
Category
(see next paragraph)
Gas rate
min.- max. (Stm
3
/h)
12 - 44.5
Gas pressure
min.- max. mbar
(Note2)
Power supply
230V - 50Hz
Total power consumption
kW
0,67/0,75
Electric motor
kW
0,37/0,45
Protection
IP40
Valves size
/
Gas connection
1” / Rp 1
1” ¼ / Rp 1
¼
1” ½ / Rp 1” ½
2” / Rp 2
Operation
Progressive - Fully modulating
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service *
Intermittent
BURNER TYPE
LG400
L-.xx...x.25
LG400
L-.xx...x.32
LG400
L-.xx...x.40
LG400
L-.xx...x.50
Output
min.- max. kW
105 - 420
Fuel
L.P.G.
Category
I
3B/P
Gas rate
min.- max. (Stm
3
/h)
4 - 16
Gas pressure
min.- max. mbar
(Note2)
Power supply
230V - 50Hz
Total power consumption
kW
0,67/0,75
Electric motor
kW
0,37/0,45
Protection
IP40
Valves size
/
Gas connection
1” / Rp 1
1” ¼ / Rp 1
¼
1” ½ / Rp 1” ½
2” / Rp 2
Operation
Progressive - Fully modulating
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service *
Intermittent
Note1:
All gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas (nett
calorific value H
i
= 34.02 MJ/Stm
3
); for L.P.G. (net calorific value H
i
= 93.5 MJ/Stm
3
)
Note2:
Maximum gas pressure = 360mbar (with
Dungs MBDLE/MBC valves)
Minimum gas pressure = see gas curves.